Table: RSP 1068 Waveform format expected:
Baud Rate
Parity
19200
Table: RSP 1068 expected format of a request by RS 232 controller:
Start
Count
Device ID
0xFE
0x03
0xa1
Table 1: Type 10 Primary Command List
NOTE: The values in the table below show the exact byte sequence of all requests. The device
will expect the bytes only - no spaces, no delimiter, etc. The controlling device may implement its
own method to download each command sequence. The numerical values in the first column are
Hexadecimal.
RSP 1068 HEX
FE 03 A1 10 00 B4
FE 03 A1 10 01 B5
FE 03 A1 10 02 B6
FE 03 A1 10 03 B7
FE 03 A1 10 04 B8
FE 03 A1 10 05 B9
FE 03 A1 10 06 BA
FE 03 A1 10 07 BB
FE 03 A1 10 08 BC
FE 03 A1 10 09 BD
FE 03 A1 10 0A BE
FE 03 A1 10 0B BF
FE 03 A1 10 0C C0
FE 03 A1 10 0D C1
FE 03 A1 10 0E C2
FE 03 A1 10 0F C3
FE 03 A1 10 10 C4
FE 03 A1 10 11 C5
FE 03 A1 10 12 C6
FE 03 A1 10 13 C7
FE 03 A1 10 14 C8
FE 03 A1 10 15 C9
FE 03 A1 10 16 CA
FE 03 A1 10 17 CB
FE 03 A1 10 18 CC
FE 03 A1 10 19 CD
FE 03 A1 10 1A CE
FE 03 A1 10 1B CF
FE 03 A1 10 1C D0
RSP 1068
RS232 Controller Command List
Valid Data Bits
N
8
Type
Key
0x10
0xXX
Command
RMC Vol+
RMC Vol-
CD
Tuner
Tape
Video 1
Video 2
Video 3
Video 4
Video 5
Power
Vol+
Vol-
Treble+
Treble-
Bass+
Bass-
Stereo
3 Stereo
Pro Logic
DSP
Multi
Dynamic
Rec
OSD Menu
OSD Enter
OSD Right (+)
OSD Left (-)
OSD Up
Stop Bit Value
Handshaking
1
Checksum
0xXX
Command Description
Remote Volume Up
Remote Volume Down
Source CD
Source Tuner
Source Tape
Source Video 1
Source Video 2
Source Video 3
Source Video 4
Source Video 5
Power Toggle
Volume Up
Volume Down
Treble Up
Treble Down
Bass Up
Bass Down
Stereo
Dolby 3 Stereo
Dolby Pro Logic
DSP Music
Multi Input
Dynamic Range
Record
OSD Menu
OSD Enter
OSD Right
OSD Left
OSD Up
Data Type
None
String

Advertisement

loading
Need help?

Need help?

Do you have a question about the RSP-1068 and is the answer not in the manual?

Questions and answers

Summary of Contents for Rotel RSP-1068

  • Page 1 RS232 Controller Command List Table: RSP 1068 Waveform format expected: Baud Rate Parity 19200 Table: RSP 1068 expected format of a request by RS 232 controller: Start Count Device ID 0xFE 0x03 0xa1 Table 1: Type 10 Primary Command List NOTE: The values in the table below show the exact byte sequence of all requests.
  • Page 2 RSP 1068 HEX FE 03 A1 10 1D D1 OSD Down / Dynamic FE 03 A1 10 1E D2 Mute FE 03 A1 10 1F D3 Digital In Select FE 03 A1 10 22 D6 Surround+ FE 03 A1 10 23 D7 Zone 2 / Main FE 03 A1 10 4A FE Power Off...
  • Page 3 Table 3: Type 14 Main Zone Command List NOTE: These commands are duplicate functions of the primary commands in the table above bearing the same name, but are discrete for the main zone only. For multi-zone installation applications, it is recommended that the below commands be used rather than the type 10 commands to avoid zone conflicts.
  • Page 4 RSP 1068 HEX FE 03 A1 16 0A C4 Zone 2 Power FE 03 A1 16 1E D8 Zone 2 Mute FE 03 A1 16 4A 04 Zone 2 Power Off FE 03 A1 16 4B 05 Zone 2 Power On FE 03 A1 16 6B 25 Zone 2 Source FE 03 A1 16 6C 26...
  • Page 5 RSP 1068 HEX FE 03 A1 32 04 DA Zone 2 Volume 4 FE 03 A1 32 05 DB Zone 2 Volume 5 FE 03 A1 32 06 DC Zone 2 Volume 6 FE 03 A1 32 07 DD Zone 2 Volume 7 FE 03 A1 32 08 DE Zone 2 Volume 8 FE 03 A1 32 09 DF...