Outputs 5-6 and 7-8 are connected in parallel, which
means that the output signal is available on each output.
Technical data
power supply voltage
minimum operating voltage
(with power from a single phase)
maximum phase voltage
frequency
cooperation with power generators
maximum load current (AC-1)
mechanical strength of contacts
electrical strength of contacts (16 A/AC-1)
TrueRMS measurement
sampling frequency of the signal
actuator
return hysteresis
setting range Vmin
setting range Vmax
voltage measurement error
switching time
return time
indication of the output voltage
power consumption
terminal
tightening torque
working temperature
dimensions
mounting
ingress protection
4.0 mm² screw terminals
- 8 -
3×230 V+N
45÷55 Hz
3× relay
160÷220 V
240÷280 V
max 200 ms
5÷300 s
0.5 Nm
-25÷50°C
2 modules (35 mm)
on TH-35 rail
85 V
420 V
no
16 A
1×10⁷
1×10⁵
yes
4 kHz
10 V
±1%
3×LED
1.5 W
IP20
Need help?
Do you have a question about the PF-421 TRMS and is the answer not in the manual?