Mains connections are exposed when the cover is removed.
Refer to wiring diagram before making any electrical connections.
Make sure all electrical connections are tight to prevent arcing/
overheating.
Make sure all plumbing connections are watertight.
When following these instructions, it is sometimes necessary to examine the
appliance with the electrical and water supplies turned on. It is therefore essential
that the appropriate safe working practices are followed in accordance with the
current Health and Safety Legislation.
If conducting a continuity check using a multimeter, make sure the electrical supply
is ISOLATED.
1.
Ensure the shower pullcord / isolator switch is in the OFF position, then turn
ON the pullcord / isolator switch.
2.
If the unit 'Beeps' & the Start / Stop button is flashing WAIT for 20 SECONDS
until the button stops flashing.
NOTE! If the Start / Stop button continues to flash & no beep was heard
upon start up, then the failure is due to a sticking switch on the Control
PCB - Refer to ERROR CODE 16 on the fault code sheet.
3.
Start the shower & observe light fault indication (if any) & refer to Error Code
Sheet to determine failure and rectify.
NOTE! If the shower operates normally run the unit for at least 5 minutes
at showering temperature & ensure the temperature remains stable.
4.
Turn the shower off at the Start / Stop Button & observe 'phased shutdown'.
DO NOT isolate the power at the pullcord / isolator switch until the water flow
stops.
5.
Turn off the power at the pullcord / isolator switch, then turn the power back
on and commission the shower.
6.
Run the shower for at least 5 minutes.
7.
Show the user the correct start / stop procedure and general operation of the
shower. Advise user that isolating the shower before the flow has stopped
may damage the shower.
For all fault codes 0 to 14 the reset light will be on or flashing. This will
require the shower to be turned off at the pullcord / isolator switch to reset
the unit. When the pullcord / isolation switch is turned back on the shower
may beep and the Start / Stop button may flash. If this occurs go back to
action number 2 and re-follow the Diagnostic Procedure.
2. DIAGNOSTIC PROCEDURE