Hand-Operated Designs; Rearming Motor Designs - Mandik SEDM-D Installation, Operation, Maintenance And Service Manual

Smoke extraction damper-multi
Table of Contents

Advertisement

Hand-operated designs

Design .24C0H
Hand-operated rearming design with a magnet voltage of
24 V DC without end switches. This design is not in
accordance with NF 61.937-1, and not in accordance with
NF 61.937-10.
Design .24C2H
Hand-operated rearming design with a magnet voltage of
24 V DC and with two end switches signaling of the
damper blade position "CLOSED" (STAND-BY) and "OPEN"
(SECURITY).
Design .24C4H
Hand-operated rearming design with a magnet voltage of
24 V DC and with two pairs of end switches signaling of
the damper blade position "CLOSED" (STAND-BY) and
"OPEN" (SECURITY).
Design .48C0H
Hand-operated rearming design with a magnet voltage of
48 V DC without end switches. This design is not in
accordance with NF 61.937-1, and not in accordance with
NF 61.937-10.
Design .48C2H
Hand-operated rearming design with a magnet voltage of
48 V DC and with two end switches signaling of the
damper blade position "CLOSED" (STAND-BY) and "OPEN"
(SECURITY).
Design .48C4H
Hand-operated rearming design with a magnet voltage of
48 V DC and with two pairs of end switches signaling of
the damper blade position "CLOSED" (STAND-BY) and
"OPEN" (SECURITY).
Page 6

Rearming motor designs

Design .24C0M
Electric motor rearming design with a magnet voltage of
24 V DC and without end switches. This design is not in
accordance with NF 61.937-1, and not in accordance with
NF 61.937-10.
Design .24C2M
Electric motor rearming design with a magnet voltage of
24 V DC, with two end switches signaling of the damper
blade position "CLOSED" (STAND-BY) and "OPEN"
(SECURITY).
Design .24C4M
Electric motor rearming design with a magnet voltage of
24 V DC, with two pairs of end switches signaling of the
damper blade position "CLOSED" (STAND-BY) and "OPEN"
(SECURITY).
Design .48C0M
Electric motor rearming design with a magnet voltage of
48 V DC without end switches. This design is not in
accordance with NF 61.937-1, and not in accordance with
NF 61.937-10.
Design .48C2M
Electric motor rearming design with a magnet voltage of
48 V DC, with two end switches signaling of the damper
blade position "CLOSED" (STAND-BY) and "OPEN"
(SECURITY).
Design .48C4M
Electric motor rearming design with a magnet voltage of
48 V DC, with two pairs of end switches signaling of the
damper blade position "CLOSED" (STAND-BY) and "OPEN"
(SECURITY).
Smoke extraction damper - SEDM-D
TPM 155/22
Version 2023-06-07

Advertisement

Table of Contents
loading

Table of Contents