Download Print this page

Advertisement

Available languages

Available languages

Quick Links

Advertisement

loading

Summary of Contents for Mandik OID

  • Page 2 ………………………………………………………......………………………………………………………………....………………………………………………………......…………………………………………………….......... ………………………………………………………………......…………………………………………........ ……………......……………………………………………......Uživatelská korekce teploty…………………………........Nastavení časového programu…………………………......... Nastavení základních požadovaných teplot a reálného času......Výchozí nastavené hodnoty regulátoru………………………......……………………………………………………......Svorky………………………………………………………....... Přepínače……………………………………………………......…………………………………………………………………......………………………………………………………………......……………………………………………………………….…...... …………………………………………..……....
  • Page 3 “ rozsvítí se zelená kontrolka el. síť „ “ na ovládací skříni a zelená kontrolka na spodku hořákové skříně (počet přepínačů se bude lišit s ohledem na provedeníovládání - OID 1 až OID 6. OID 1 ovládá 1ks zářiče Helios, OID 6 ovládá 6ks zářičů Helios) 3.
  • Page 4 1. Přepínač „ - STOP - “ přepnete do polohy „STOP“. 2. Při dlouhodobém odstavení z provozu je vhodné zavřít plynový ventil před zářičem. UC301 je komunikativní dvoustupňový regulátor plynových zářičů s výstupy SSR. Může buď pracovat autonomně, nebo být připojen na primární regulátor (MiniPLC nebo SoftPLC), vizualizaci (RcWare Vision nebo jiný...
  • Page 5 Externí čidlo se používá v případech, kdy regulátor je instalován na místě, kde není možné korektně měřit teplotu. Použijte analogové čidlo Pt1000 v provedení do místnosti, do průmyslu (s vyšší odolnos- tí) nebo venkovním (vyšší krytí). Pokud není čidlo připojeno (svorky rozpojeny), automaticky se bere teplota z interního čidla.
  • Page 6 Po – Pá 6:00 ... 15:00 komfort, jinak útlum ● So – Ne trvale útlum ● Regulace podle interního čidla (přepnutí teplotního čidla se provádí přepínačem na zadní straně regulátoru-viz níže) Teplota pro útlum 15 C, pro komfort 19 C ●...
  • Page 7 1: K- komunikace RS485 - 2: K+ komunikace RS485 + 3: DO1 výstup pro topení, 1. stupeň proti G0 4: N/C nevyužito 5: DO2 výstup pro topení, 2. stupeň proti G0 6: - napájení minus, výstupy – vztažný bod 7: + napájení...
  • Page 8 Regulátory jsou určeny pro provoz v běžném, chemicky neagresivním prostředí. Nevyžadují údržbu. Montují se ve svislé poloze do míst, kde jsou snadno přístupné pro ovládání a kde správně měří teplotu v místnosti, tedy asi ve výšce 150 cm, na stinné straně, mimo průvan a vliv zdrojů tepla a chladu (vyústky klimatizace, chladnička, el.
  • Page 9 Výchozí hodnoty a další parametry regulátoru (PI konstanty, adresa, přenosová rychlost...) je možné nastavit konfiguračním programem ModComTool přes převodník RS232/RS485 nebo USB/RS485. Vhodné typy kabelů jsou LAM DATAPAR 2x0.8 (průřez mm ), JYTY 2x1 (průměr mm) apod. Pokud ve stejném kabelu povede i komunikace, použijte čtyřžilové kabely LAM DATAPAR 2x2x0.8, JYTY 4x1. Při vzdálenostech desítek metrů...
  • Page 12 ………………………………………..…………………………… ……………………………………………………………......………………………………………..……………………………. ……………………… ……………………………………............. User temperature correction…………………………........Setting the time program………………………….......... Setting basic desired temperatures and real time.......... Default regulator settings………………………..........………………………………………..…………..Terminals………………………………………………………......Switches.……………………………….…………………........ ………………………………………..……………………………..……………………………………………………………......………………………………………………………….…......………………………………………..……....
  • Page 13 “ the electric network green indicator light will light up „ “ on the control box. (the number of switches will vary depending on the type of control box - OID 1 to OID 6. OID 1 controls 1 Helios heater, OID 6 controls 6 Helios heaters) 3.
  • Page 14 1. Turn the „ - STOP - “ switch to the „STOP“ position. 2. When the radiator is shut off for a long time, it is advisable to close the gas valve. The UC301 is a communication two-stage regulator for gas heaters with SSR outputs. It can work autonomously or be connected to a primary regulator (MiniPLC or SoftPLC), visualization (RcWare Vision or other SCADA system) or UCWEB web interface.
  • Page 15 The external sensor is used in cases when the regulator is installed in a place where it is not possible to measure the temperature correctly. Use the analog sensor Pt1000 designed for rooms, industrial spaces (high resistance) or the outdoors (higher coverage). The temperature range of the external sensor is -20 to +50 °C.
  • Page 16 ● Mon – Fri 6:00 ... 3:00pm Comfort, otherwise Economy Sat – Sun permanently Economy Regulation according to internal sensor (switching the temperature sensor is performed with ● a switch on the back of the regulator, see below) Economy temperature 15 C, Comfort temperature 19 C ●...
  • Page 17 1: K- RS 485 communication - 2: K+ RS 485 communication+ 3: DO1 output heating, 1st stage 4: N/C not used 5: DO2 output heating, 2nd stage 6: - Power supply – pole, reference 7: + Power supply + pole 8: AIN external temperature sensor Pt1000 9: AGND...
  • Page 18 The regulators are designed to operate in a normal non-corrosive indoor environment. They don't require maintenance. They are installed vertically in places where they are easily accessible for control and where they properly measure the room temperature, which is at about a height of 150 cm in the shade, away from drafts and sources of heat and cold (air conditioner outlets, refrigerator, electric appliances).
  • Page 19 Default values and other regulator parameters (PID constants, address, baud rate...) can be set in the configuration program ModComTool via converter RS232/RS485 or USB/RS485. Suitable cable types are LAM DATAPAR 2x0.8 (diameter mm ), JYTY 2x1 (diameter mm) etc. If the communication will lead through the same cable, use four conductor cables LAM DATAPAR 2x2x0.8, JYTY 4x1.
  • Page 22 ………........... ……………………………………..……………………......……........... ………................................. Benutzer definierte kurzfristige Solltemperatur Korrektur......Einstellen eines Zeitprogramms..…………………......... Einstellen der grundlegenden Sollwerte und der Echtzeit......Standardwerte…..…………………............….…. Standardeingestellte Regulator Werte………..........………………………………………………......Klemmen…………………………...………………………....... Schalter……………………………………………..…......…..………..…………………………………………………….....…. ……………………………………………………………......……………………………………………………….…....... Interne Schaltschema Steuerung OID......…......….
  • Page 23 Dunkelstrahler angeschlossen werden, wo die Zahl der gesteuerten Dunkelstrahler bei einer Bestellung angegeben werden muss und wird dann durch die Typen Nummer OID 1 bis OID 6 klar fixiert. Das OID Steuersystem ist für eine automatische 1 Zonen Steuerung von 2- stufigen Dunkelstrahlern vorgesehen.
  • Page 24 Den dreistufigen Schalter 2 „ - STOP - “ in die Position „STOP“ umschalten. Bei einer langfristigen Abschaltung sollte das Gasventil vor dem Dunkelstrahler geschlossen werden. Regler MANDÍK UC301 ist ein kommunikativer zweistufiger Gasheizungsregler mit SSR-Ausgängen. Er kann entweder selbstständig arbeiten oder an einen primären Regulator (Mini-PLC oder Soft-PLC), eine Visualisierung (RcWare-Vision oder ein anderes SCADA-System) oder ein Web-Interface UCWEB angeschlossen werden.
  • Page 25 Der externe Temperatur Sensor wird in Fällen genutzt, in denen der Regler an einem Ort installiert ist, wo es nicht möglich ist, die Temperatur korrekt zu messen. Verwenden Sie den Analogsensor Pt1000 in der Durchführung für Zimmer, Industrie (höhere Robustheit) oder Außenbereiche (höhere Abdec- kung).
  • Page 26 Schalten Sie in den Einstellungsmodus mit einem langen Tastendruck um (> 5 s) des Drehknopfs um. Der Regler schaltet in ein Modus um, in welchem die gewünschten Solltemperaturen für die jeweiligen Betriebsarten eingestellt werden (wird durch eine Thermometer-Ikone angezeigt) und auch die Regler interne Uhrzeit.
  • Page 27 Stromversorgung 24 V DC +/- 10% Stromverbrauch 600 mVA + Peripherie (ca. 5VA) interner Sensor 0 bis 50°C Temperatur Messbereich externer Fühler -20°C bis 50°C Schutzart IP20 Sensorgenauigkeit +/- 1,5 K (Option Software-Korrektur) 2x SSR mit Null-Schaltung für gleichförmige oder Ausgänge wechselhafte Belastung, 24 V AC / DC, maximaler geschalteter Strom 0,4 A, für Relais-Schaltung...
  • Page 28 1: K- Kommunikation RS485 - 2: K+ Kommunikation RS485 + 3: DO1 Heizausgang, 1. Stufe gegen G0 4: N/C Ungenutzt 5: DO2 Heizausgang, 2. Stufe gegen G0 Stromversorgung Minus; 6: - Ausgänge - Bezugspunkt 7: + Stromversorgung Plus 8: AIN Externer Temperatur Sensor P 1000 9: AGND Externer Temperatur Sensor P 1000...
  • Page 29 Die Regler sind für den Betrieb in einer normalen und chemisch nicht aggressiven Umgebung bestimmt. Sie benötigen keine Wartung. Sie werden in einer vertikalen Position in die Stellen montiert, wo sie leicht zugänglich sind und wo sie die Raumtemperatur richtig messen, also ca. in einer Höhe von 150 cm, auf der Schattenseite, außerhalb von Zugluft und Einfluss von Wärmequellen und Kältequellen (Mündungen von Klimaanlage, Kühlschrank, el.
  • Page 31 CYKY 5J x 1,5 Netzanschlussleitung 230V / 50HZ Anm: Der Fühler wird auf Wunsch des Investors angeschlossen JYTY 2x1 (geschirmt) JYTY 7x1 (Max. Abstand 30m) (Max. Abstand 10m)
  • Page 32 MANDÍK, a.s. Dobříšská 550 26724 Hostomice Česká republika Tel.: +420 311 706 706 E-Mail: mandik@mandik.cz www.mandik.cz MANDÍK, a.s. MANDÍK, a.s. MANDÍK GmbH Dobříšská 550 Dobříšská 550 Veit-Stoß-Straße 12 26724 Hostomice 26724 Hostomice 92637 Weiden Czech Republic Tschechische Republik Deutschland Tel.: +420 311 706 706 Tel.: +420 311 706 742...

This manual is also suitable for:

Uc301