●MASKED WRITE
Status
Data Byte
F0H
7FH,Dev,06H,41H,04H,
ddH,eeH,ffH,ggH
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive
Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
41H
MASKED WRITE
04H
Number of Bytes follows the command
ddH
The name of the masked type writable Information Field
eeH
Byte number to write in the Bit Map
ffH
bit location of the bit map byte to change
ggH
New data to write to the specified bit map byte
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD writes the data to the specified bit map byte.
The VS-2480/2480CD does not transmit this message.
●LOCATE(MCP)
❍Format 1 - LOCATE[I/F]
Status
Data Byte
F0H
7FH,Dev,06H,44H,02H,00H,nnH
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive
Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
44H
LOCATE(MCP)
02H
Number of Bytes
00H
"I/F" sub command
nnH
Information Field (08H, 09H, 0AH, 0BH, 0CH, 0DH, 0EH, 0FH)
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD locates the selected time location stored to the specified information filed.
The VS-2480/2480CD does not transmit this message.
❍Format 2 - LOCATE[TARGET]
Status
Data Byte
F0H
7FH,Dev,06H,44H,06H,01H,
hrH,mnH,scH,frH,ffH
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive
Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
44H
LOCATE(MCP)
06H
Number of Bytes
01H
"TARGET" sub command
hrH,mnH,scH,frH,ffH
Standard time with Sub Frame
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD locates the specified time location received from the command.
If the efficient locate number or marker number is selected, the VS-2480/2480CD transmits
as the device ID 7FH.
●MOVE
Status
Status
F7H
F0H
Byte
F0H
7FH
Dev
06H
4CH
02H
ddH
ssH
F7H
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD transfers the data on the selected source information filed to the
destination Information Field, if the name of both information fields in efficient.
The VS-2480/2480CD does not transmit this message.
●The efficient Information Field
The followings are the efficient Information Field on the VS-2480/2480CD.
The name of the efficient destination Information Field:
Status
F7H

4. Bulk Dump

VS-2480/2480CD can transfer and receive the scenes, the EZ ROUTING User Templates and
the User Effect Patches by bulk dump.
In order to make bulk dump transmit, a transmitting function is performed on UTILITY-
MIDI BULK DUMP screen.
In order to make bulk dump receive, after changing into a reception standby state on
Status
UTILITY-MIDI BULK DUMP screen, the bulk dump which the VS-2480/2480CD outputted
F7H
beforehand is sent to the VS-2480/2480CD.
■Address Block
+———————————————————————————————————————————————————————————————————————————+
| Start
|
|=============+=============================================================|
| 10 00 00 00 | SCENE #00
| 10 00 7F 7F |
|—————————————+—————————————————————————————————————————————————————————————|
| 10 01 00 00 | SCENE #01
| 10 01 7F 7F |
|—————————————+—————————————————————————————————————————————————————————————|
|—————————————+—————————————————————————————————————————————————————————————|
| 10 63 00 00 | SCENE #99
| 10 63 7F 7F |
|—————————————+—————————————————————————————————————————————————————————————|
| 11 00 00 00 | EZ ROUTING USER TEMPLATE #00
| 11 00 7F 7F |
|—————————————+—————————————————————————————————————————————————————————————|
| 11 01 00 00 | EZ ROUTING USER TEMPLATE #01
| 11 01 7F 7F |
|—————————————+—————————————————————————————————————————————————————————————|
|—————————————+—————————————————————————————————————————————————————————————|
| 11 13 00 00 | EZ ROUTING USER TEMPLATE #19
| 11 13 7F 7F |
|—————————————+—————————————————————————————————————————————————————————————|
| 12 00 00 00 | EFFECT USER PATCH #000
| 12 00 01 7F |
|—————————————+—————————————————————————————————————————————————————————————|
| 12 00 02 00 | EFFECT USER PATCH #001
| 12 00 03 7F |
|—————————————+—————————————————————————————————————————————————————————————|
|—————————————+—————————————————————————————————————————————————————————————|
| 12 03 0E 00 | EFFECT USER PATCH #199
| 12 03 0F 7F |
+———————————————————————————————————————————————————————————————————————————+
MIDI Implementation
Data Byte
7FH,Dev,06H,4CH,02H,ddH,ssH
Description
Status of System Exclusive Message
Universal System Exclusive
Realtime Header
Device ID (or 7FH)
MMC Command Message
MOVE
Number of Bytes
Name of the Efficient Destination Information Field
(08H,09H,0AH,0BH,0CH,0DH,0EH,0FH)
Name of the Efficient Source Information Field
EOX (End of Exclusive Message)
01H SELECTED TIME CODE
08H GP0 / LOCATE POINT
09H GP1
0AH GP2
0BH GP3
0CH GP4
0DH GP5
0EH GP6
0FH GP7
4FH TRACK RECORD READY
|
address |
Contents and remarks
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
Status
F7H
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
117