MIDI Implementation

3. MIDI Machine Control

■MIDI Machine Control Details
●STOP(MCS)
Status
Data Byte
F0H
7FH,Dev,06H,01H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive
Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
01H
STOP (MCS)
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD stops immediately.
If the transport switch [STOP] was pressed, the VS-2480/2480CD transmits as the device ID
7FH.
●PLAY(MCS)
Status
Data Byte
F0H
7FH,Dev,06H,02H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive
Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
02H
PLAY(MCS)
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD goes into the playback condition.
The VS-2480/2480CD does not transmit this message.
●DEFERRED PLAY(MCS)
Status
Data Byte
F0H
7FH,Dev,06H,03H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive
Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
03H
DEFERRED PLAY(MCS)
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD goes into the playback condition after the locate operation.
If the transport switch [PLAY] was pressed, the VS-2480/2480CD transmits as the device ID
7FH.
●FAST FORWARD(MCS)
Status
Data Byte
F0H
7FH,Dev,06H,04H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive
Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
04H
FAST FORWARD(MCS)
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD goes into the fast forward condition.
The VS-2480/2480CD does not transmit this message.
●REWIND(MCS)
Status
Data Byte
F0H
7FH,Dev,06H,05H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive
Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
05H
REWIND(MCS)
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD goes into the rewind condition.
The VS-2480/2480CD does not transmit this message.
116
Status
F7H
Status
F7H
Status
F7H
Status
F7H
Status
F7H
●RECORD STROBE
Status
Data Byte
F0H
7FH,Dev,06H,06H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive
Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
06H
RECORD STROBE
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD goes into the following condition.
1. The VS-2480/2480CD is in the playback condition. Start Recording the tracks that status
are the record standby mode.
2. The VS-2480/2480CD is in the stop condition. Start Playing back and Start Recording the
track that status are the record standby mode.
If the transport switch [REC] was pressed out of the recording condition, he VS-2480/
2480CD transmits as the device ID 7FH.
●RECORD EXIT
Status
Data Byte
F0H
7FH,Dev,06H,07H
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive
Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
07H
RECORD EXIT
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD exit from the record condition.
If the transport switch [REC] was pressed while recording, the VS-2480/2480CD transmits
as the device ID 7FH.
●MMC RESET
Status
Data Byte
F0H
7FH,Dev,06H,0DH
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive
Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
0DH
MMC RESET
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD resets all communication channels related with MMC.
When powered on the VS-2480/2480CD transmits as the device ID 7FH.
●WRITE
Status
Data Byte
F0H
7FH,Dev,06H,40H,
ccH,ddH,eeH,,,ffH,,,
Byte
Description
F0H
Status of System Exclusive Message
7FH
Universal System Exclusive
Realtime Header
Dev
Device ID (or 7FH)
06H
MMC Command Message
40H
WRITE
ccH
Information Bytes follows the command
ddH
The name of the writable Information Field.
eeH
Information Field Format
:
:
ffH
Field names and data
:
:
F7H
EOX (End of Exclusive Message)
If the device ID on the message was as same as that of the receiving device or 7FH, the
VS-2480/2480CD write the data to the specified information field.
The VS-2480/2480CD does not transmit this message.
Status
F7H
Status
F7H
Status
F7H
Status
F7H