Control Panel Components - Magnum MPG 6600 Operating & Parts Manual

Table of Contents

Advertisement

CONTROL PANEL COMPONENTS

MPG 6600
A.
ENGINE START SWITCH: This switch must be in the ON position to start the engine. To stop the engine,
place switch in OFF position.
B.
AUTO IDLE SWITCH: When this switch is engaged, the engine speed will return to idle whenever the
generator is not under load.
C.
ENGINE START: Push button for electric engine starting option.
D.
VOLTAGE SWITCH: This switch changes voltage on the L14-30R outlet from 120V to 240V.
E.
MAIN CIRCUIT BREAKER: This unit contains a 28A circuit breaker.
F.
GFCI TEST MODULE: This module is the ground fault circuit interrupter to protect all electrical outlets.
G.
120/240V TWIST-LOCK CONVENIENCE OUTLET: This L14-30R outlet is used to connect additional loads or
equipment to the generator.
H.
120V TWIST-LOCK CONVENIENCE OUTLET: This L5-30R outlet is used to connect additional loads or
equipment to the generator.
I.
120V DUPLEX CONVENIENCE OUTLETS: These 120V outlets are used to connect additional loads or
equipment to the generator.