Installation

5.5 Installation on a standard S7-1500 rail

5.5
Installation on a standard S7-1500 rail
Installing on an S7-1500 standard rail
Figure 5-3
To screw the device to an S7-1500 standard rail, you require a securing screw with the following
properties:
• Self-tapping screw 4 x 45 mm
• Screw head diameter: max. 7 mm
To install the device on an S7-1500 standard rail, follow the steps below:
1. Place the first housing guide of the device on the top edge of the standard rail
2. Screw the device to the lower part of the standard rail with the supplied securing screw
(tightening torque 1.5 Nm), see also "Device views (Page 21)".
Removal
To remove the device from a standard rail, follow the steps below:
1. Release the screw on the underside of the standard rail.
2. If the extender is connected to a basic device, disconnect the extender, see section "Fitting
an extender (Page 37)".
3. Remove the device from the standard rail.
36
S7-1500 standard rail mounting
Extender for SCALANCE XM-400
Operating Instructions, 03/2021, C79000-G8976-C332-10
.