Technical specifications of the PE400-8SFP

The following technical specifications apply to the port extender PE400-8SFP.
Technical specifications
Attachment to Industrial Ethernet
Slots for SFP transceivers
Electrical data (supply from basic device)
Current consumption
Effective power loss
Permitted ambient conditions
Ambient temperature/
In areas according to UL508 or CSA C22.2
No.142: Temperature of the ambient air
Relative humidity
Design, dimensions and weight
Degree of protection
Weight
Dimensions (W x H x D)
Installation options
Mean time between failure (MTBF)
*) You will find the precise values in the operating instructions of the pluggable transceiver, see
section "Introduction (Page 5)", subsection "Further documentation".
Extender for SCALANCE XM-400
Operating Instructions, 03/2021, C79000-G8976-C332-10
Quantity
Connector
Transmission speed
at 24 V DC
at 24 V DC
During operation up to 2000 m
During operation up to 3000 m
During storage
During transportation
During operation at 25 °C
IP20
600 g
70 x 150 x 125 mm
Installation on a DIN rail
Installation on an S7-300 standard rail
Installation on an S7-1500 standard rail
at 40 °C ambient temperature
Technical specifications
7.3 Technical specifications of the PE400-8SFP
8
SFP transceivers
(LC port)
100 / 1000 Mbps
without SFP transceiver
depending on the SFP
transceiver
without SFP transceiver
depending on the SFP
transceiver *
)
-40 °C to +60 °C
-40 °C to +55 °C
-40 °C to +85 °C
-40 °C to +85 °C
≤ 95 %, no condensation
63 years
70 mA
max. 210
mA
1.7 W
max. 5 W
49