Advertisement

Quick Links

XTS166 RC
OPERATOR MANUAL
ISSUE 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XTS166 RC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Parweld XTS166 RC

  • Page 1 XTS166 RC OPERATOR MANUAL ISSUE 2...
  • Page 2 Thank you and congratulations on choosing Parweld. This Owner’s Manual is designed to help you get the most out of your Parweld products. Please take time to read the Safety precautions. They will help you protect yourself against potential hazards in the workplace. With proper maintenance this equipment should provide years of reliable service.
  • Page 3: Table Of Contents

    Contents Page 1.0 Safety Precautions 2.0 Product description 3.0 Technical Specifications 4.0 Description of controls 5.0 Installation 5.1 Unpacking the Machine 5.2 Location 5.3 Input and grounding connection 5.4 Output Polarity Connections 5.5 Torch Installation 5.6 Work return lead connection 6.0 Operation 6.1 MMA Welding guide 6.2 Basic TIG welding guide...
  • Page 4: Safety Precautions

    Insulate work clamp when not connected to work piece to prevent contact with any metal object. Protect yourself and others from flying sparks and hot metal. Be alert that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. www.parweld.co.uk...
  • Page 5: Product Description

    Turn face away from valve outlet when opening cylinder valve. Use the right equipment, correct procedures, and sufficient number of persons to lift and move cylinders. www.parweld.co.uk...
  • Page 6: Description Of Controls

    Operate the welding power source from a single-phase 50/60 Hz, welding amperage during welding. AC power supply. The XTS166 RC machine can be used on 230v or 5) Remote control connection allows the connection of a remote 110V supply without modifiying the machine in any way.
  • Page 7: Torch Installation

    These include some low hydrogen types for high tensile steel, cellulose types for welding large diameter pipes, etc. The range of electrodes dealt with in this publication will cover the vast majority of applications likely to be www.parweld.co.uk...
  • Page 8: Fault Finding

    (d) Travel speed of current electrode is too high (c) Adjust (e) Scale or dirt on joint angle so the surface welding arc is directed more into the base metal (d) Reduce travel speed of electrode (e) Clean surface before welding. www.parweld.co.uk...
  • Page 9 Weld bead too Welding current is too Decrease weld wide and flat high current or undercut at edges of weld or excessive burn through www.parweld.co.uk...
  • Page 10 Welding Poor work lead Ensure that the current connection to the work work lead has a reduces when piece reliable electrical welding connection to the work piece www.parweld.co.uk...
  • Page 11: Accessories

    • Fitted with standard ” BSP inlet and outlet connections Stock Code Description 706100 Flow Meter Mixed Gas 15 lpm 8.3 Remote Control Remote control pendant allows full amptage range adjustment Stock Code Description RC1040-19 Remote Pendant with 4m lead and plug www.parweld.co.uk...
  • Page 12 Air Cooled TIG Welding Torch 3/89 BSP Model Description Stock Code 12ft (3.8m) 25ft (7.6m) Valved Tig Torch c/w 2 Piece Power Cable and dinse connection WP17V-12-2-IX WP17V-25-2-IX Valved Flexible neck Tig Torch c/w 2 Piece Power Cable and dinse connection WP17VFX-12-2-IX WP17VFX-25-2-IX www.parweld.co.uk...
  • Page 13 45V29 Gas Lens Body .020”/0.5mm Bore 19 WP17VFX Torch Body Flexi-Valve 45V24 Gas Lens Body .040”/1.0mm Bore NI – Not Illustrated 45V25 Gas Lens Body 1/16”/1.6mm Bore 45V26 Gas Lens Body 3/32”/2.4mm Bore 45V27 Gas Lens Body 1/8”/3.2mm Bore www.parweld.co.uk...
  • Page 14: Ec Declaration Of Conformity

    9.0 EC declaration of conformity Hereby we declare that the machines as stated below Type: XTS166 RC Conform to the EC Directives: Low Voltage Directive 2014/35/EEC EMC Directive 2014/35/EEC Harmonised European standard: EN/IEC 60974-1 This is to certify that the tested sample is in conformity with all provisions of the above detailed EU directives and product standards.
  • Page 15: Weee Statement

    WEE compliance outside the UK please contact your supplier/Importer Parweld is registered with a compliance scheme Official registration number is WEE/FD0255QV When your equipment reaches the end of its service life you should return it to Parweld where it will be reconditioned or processed for recycling.
  • Page 16 Parweld Limited Bewdley Business Park Long Bank Bewdley Worcestershire England DY12 2TZ Tel. +44 1299 266800 Fax. +44 1299 266900 www.parweld.co.uk info@parweld.co.uk...

Table of Contents