Download Print this page
Hide thumbs Also See for SR-Series:

Advertisement

Quick Links

Introduction
Scope
This document aims to provide a user manual for the setup and installation of the SR-Series
sensor by Magos Systems. The manual provides information on mechanical structure and
interface, installation procedure and guidelines, and interface to manage the system.
Please read the entire document prior to the installation and or use of the product.
About Magos Systems
Magos was established in 2008 to realize its co-founder's vision of bringing advanced radar
technology to the security, perimeter protection, and detection market. We are experts in
low-cost & power consumption and high-performance radars that can be easily integrated
with existing VMS, PSIM, and other control software and automatic PTZ slew to cue for an
end-to-end cost-effective and easily maintained solution for the customer's security
requirements.
©2023, Magos Systems Ltd. All rights reserved.
SR-Series
User Manual

Advertisement

loading

Summary of Contents for Magos SR-Series

  • Page 1 Introduction Scope This document aims to provide a user manual for the setup and installation of the SR-Series sensor by Magos Systems. The manual provides information on mechanical structure and interface, installation procedure and guidelines, and interface to manage the system.
  • Page 2 They provide accurate location, velocity, and bearing data on moving targets within their coverage area. The SR-series sensor is a radar technology-based sensor. This means that it transmits low-power (less than 100mW) RF signal in the C-Band frequency and inspects the returned signal.
  • Page 3 3Kg / 6.6Ib Approvals/ CE, FCC, UL, IC FCC, UL, IC FCC, UL, IC FCC, UL, IC CE/RED EN 62368- Certifications 1:2014, EN 60950- 22:2006 / AC:2008, EN 301 489-1, EN 301 489-3, EN 300 ©2023, Magos Systems Ltd. All rights reserved.
  • Page 4 Figure 1: SR-Series Sensors – SR150/250/500 (left) and SR1000/SCEPTER (right) ©2023, Magos Systems Ltd. All rights reserved.
  • Page 5: Physical Installation

    Installation of the SR-Series Sensors is intended for technicians/system integrators who have only received training by Magos Ltd. If you have not received proper training, please contact Magos Ltd or visit our website (www.magosys.com) for a list of authorized installation personnel.
  • Page 6 Use tripods only for evaluating sensor performance during site surveys/demos/etc. In general water is non-transparent to RF signals. A consequence of this fact is that when the SR-series sensor intended to cover an area containing large bodies of ©2023, Magos Systems Ltd. All rights reserved.
  • Page 7 Figure 3 and Figure 4 outline the mechanical dimensions of the various sensors and the with ¼’’-20X1/2 screws. Screws and mounting brackets can be purchased separately from locations of the mounting holes (identical in all SR-series models). Holes are compatible Magos. These include tilt adjustable brackets, and adaptors for wall, corner, and pole installations as depicted in.
  • Page 8 Figure 3: SR-1000F/SCEPTER Mechanical Dimensions and Mounting Holes Figure 4: SR-500F/SR-500I/SR-250F/SR-150F Mechanical Dimensions and Mounting Holes ©2023, Magos Systems Ltd. All rights reserved.
  • Page 9 Therefore, please use the following table as a minimum recommended radar installation height as a function of the maximum detection range wanted for the radar: Range (m) Sensor Minimum Height (m) 1000 Table 2: Recommended Installation Height ©2023, Magos Systems Ltd. All rights reserved.
  • Page 10 Figure 6: SR-Series Maximum Coverage Diagram (Top View) In terms of tilt angle, to achieve the best performance refer to Table 3 and Figure 7.
  • Page 11 Figure 7: Tilt Angle Height (m) Range (m) Tilt angle (degrees) Table 3: Tilt Angle ©2023, Magos Systems Ltd. All rights reserved.
  • Page 12 In addition, make sure that the cable securing method renders it resistible to strong winds and that it does not apply excessive force on the connector. ©2023, Magos Systems Ltd. All rights reserved.
  • Page 13: Electrical Installation Guidelines

    Figure 8: SE-Series External operation cable Power Supply Interface Ensure that the SR-Series radar is powered only by an IEEE 802.3at Type 1 (802.3af) and Type 2 certified POE injector/switch which is in conformance with all safety and EMC standards that are relevant and applicable in your country. If you are unfamiliar with such standards, it is recommended that you contact Magos and enquire as to the compatibility of the suggested power supply.
  • Page 14 Network Behavior In terms of network discovery – the SR-Series sensors send out a broadcast message used for the identification of the sensor in any network, regardless of the subnet. These messages can be used for the initial detection and configuration of the sensor (setting a subnet-matching IP address).
  • Page 15 IP was indeed updated successfully. This IP will be retained in flash memory on the sensor and will not be erased upon reset. It can be re-configured using the radar manager tool whenever needed. ©2023, Magos Systems Ltd. All rights reserved.
  • Page 16 Note – The BIT feature is not supported in all FW versions. In order to find out whether your sensor supports BIT please contact the Magos support team. BIT Mechanism The built-in test contains 2 types of tests – continuous and periodic. Continuous tests are run continuously.
  • Page 17 Magos personnel or an authorized technician to ensure that no lasting damage has occurred. In case of failure in all other tests, the unit must be inspected by Magos personnel or an authorized technician in order to locate the HW fault and repair it.
  • Page 18: Warnings And Disclaimers

    Warnings and Disclaimers General The SR-series sensor is an electronic radiating product. As such it is not recommended for installation in densely populated areas, or in the vicinity of such areas. Magos recommends installation at remote, un-populated, outdoor sites only. In addition, avoid prolonged unnecessary human contact with the radar and as a rule, it is recommended that the sensor is installed at a safety distance of at least 3m from any person.
  • Page 19 A distance of at least 30cm. between the equipment and all persons should be maintained during the operation of the equipment. ©2023, Magos Systems Ltd. All rights reserved.
  • Page 20 Transport in case of a malfunction that requires maintenance at Magos premises is under the responsibility of the customer. Magos Ltd does not have any liability or responsibility under the Product Warranty where any cost, loss, injury, or damage of any kind, whether direct, indirect, consequential, incidental or otherwise arises out of events beyond Magos’s reasonable control.
  • Page 21 (ii) in the case of a supply of services, Magos doing either or both of the following: supplying the services again, or paying the cost of having the services supplied again.