To Connect The Alarm Output; Output - Daikin Altherma 3 R MT W Installation Manual

Table of Contents

Advertisement

1 Front panel
2 Switch box cover
3 Switch box
2 Connect the domestic hot water pump cable to the appropriate
terminals as shown in the illustration below.
A
A
B
C
B
C
X2M
3 Fix the cable with cable ties to the cable tie mountings.
6.3.6

To connect the alarm output

Wires: (2+1)×0.75 mm²
Maximum load: 0.3 A, 250 V AC
[9.D] Alarm output
1 Open the following (see
"4.2.1 To open the indoor
1 Front panel
2 Switch box cover
3 Switch box
2 Connect the alarm output cable to the appropriate terminals as
shown in the illustration below.
1+2
2
1
X2M
7
9
A4P Installation of EKRP1HBAA is
3
A4P
Y1
YC
ELBH/X12E
Daikin Altherma 3 R MT W
4P708482-1 – 2023.03
3
2
1
M
1~
M2P
1 2
X2M
unit" [ 4  11]):
3
2
1
Wires connected to the alarm

output

3
Wire between X2M and A4P
required.
A
A
B
C
B
C
X2M
A4P
a
Installation of EKRP1HBAA is required.
3 Fix the cable with cable ties to the cable tie mountings.
6.3.7
To connect the space cooling/heating ON/
OFF output
INFORMATION
Cooling is only applicable in case of reversible models.
Wires: (2+1)×0.75 mm²
Maximum load: 0.3 A, 250 V AC
1 Open the following (see
"4.2.1 To open the indoor
1 Front panel
2 Switch box cover
3 Switch box
2 Connect the space cooling/heating ON/OFF output cable to the
appropriate terminals as shown in the illustration below.
1+2
2
1
X2M
7
9
A4P Installation of EKRP1HBAA is
3
A4P
Y2
YC
6 Electrical installation
Y1
7
7
9
X2M
A4P
X1M
YC
Y1
a
unit" [ 4  11]):
3
2
1
Wires connected to the space
cooling/heating ON/OFF
output
3
Wire between X2M and A4P
required.
Installation manual
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elbx-e6v

Table of Contents