6 Electrical installation
WARNING
▪ All wiring MUST be performed by an authorised
electrician and MUST comply with the applicable
national wiring regulation.
▪ Make electrical connections to the fixed wiring.
▪ All components procured on-site and all electrical
construction
MUST
legislation.
WARNING
ALWAYS use multicore cable for power supply cables.
WARNING
If the supply cord is damaged, it MUST be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
CAUTION
Do NOT push or place redundant cable length into the unit.
INFORMATION
When installing field supply or option cables, foresee
sufficient cable length. This will make it possible to open
the switch box and gain access to other components
during service.
6.1

About electrical compliance

Only for the backup heater of the indoor unit
See
"6.3.2 To connect the backup heater power
6.2
Guidelines when connecting the
electrical wiring
Tightening torques
Indoor unit:
Item
X1M
X2M
X5M
X6M
X7M, X8M
X10M
M4 (earth)
6.3

Connections to the indoor unit

Item
Power supply (main)
See
"6.3.1 To connect the main power
supply" [ 4  17].
Power supply (backup
See
"6.3.2 To connect the backup heater
supply" [ 4  18].
heater)
power
Shut-off valve
See
"6.3.3 To connect the shut-off
valve" [ 4  20].
Electricity meters
See
"6.3.4 To connect the electricity
meters" [ 4  20].
Domestic hot water
See
"6.3.5 To connect the domestic hot
pump" [ 4  20].
pump
water
Alarm output
See
"6.3.6 To connect the alarm
output" [ 4  21].
Space cooling/heating
See
"6.3.7 To connect the space cooling/
operation control
heating ON/OFF
Installation manual
16
comply
with
the
applicable
supply" [ 4  18].
Tightening torque (N•m)
2.45 ±10%
0.88 ±10%
0.88 ±10%
2.45 ±10%
2.45 ±10%
0.88 ±10%
1.47 ±10%
Description
output" [ 4  21].
Item
Changeover to
See
"6.3.8 To connect the changeover to
external heat source
external heat
control
Power consumption
See
"6.3.9 To connect the power
digital inputs
consumption digital
Safety thermostat
See
"6.3.10 To connect the safety
thermostat (normally closed
contact)" [ 4  23].
Smart Grid
See
"6.3.11 To connect a Smart
Grid" [ 4  23].
WLAN cartridge
See
"6.3.12 To connect the WLAN
cartridge (delivered as
Room thermostat
See below table.
(wired or wireless)
Wires: 0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪ [2.9] Control
▪ [2.A] Ext thermostat type
For the additional zone:
▪ [3.A] Ext thermostat type
▪ [3.9] (read-only) Control
Heat pump convector
There are different controllers and
setups possible for the heat pump
convectors.
Depending on the setup, you also
need to implement a relay (field
supply, see addendum book for
optional equipment).
For more information, see:
▪ Installation manual of the heat
▪ Installation manual of the heat
▪ Addendum
Wires: 0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪ [2.9] Control
▪ [2.A] Ext thermostat type
For the additional zone:
▪ [3.A] Ext thermostat type
▪ [3.9] (read-only) Control
Remote outdoor
See:
sensor
▪ Installation manual of the remote
▪ Addendum
Wires: 2×0.75 mm²
[9.B.1]=1 (External sensor =
Outdoor)
[9.B.2] Ext. amb. sensor offset
[9.B.3] Averaging time
Description
source" [ 4  22].
inputs" [ 4  22].
accessory)" [ 4  25].
pump convectors
pump convector options
book
for
optional
equipment
outdoor sensor
book
for
optional
equipment
ELBH/X12E
Daikin Altherma 3 R MT W
4P708482-1 – 2023.03

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elbx-e6v

Table of Contents