13
|
Maintenance and service

13.4.3 To install the water filter

Installer reference guide
244
b
a
a Bottom part to be unscrewed
b Water filter housing
3 Remove the strainer and the rolled‑up filter from the water filter housing and
clean with water.
4 Install the cleaned rolled‑up filter and strainer in the water filter housing.
INFORMATION
Correctly install the strainer in the magnetic filter/dirt separator housing using the
protrusions.
c
b
c
a Rolled‑up filter
b Strainer
c Protrusion
5 Install and properly tighten the bottom of the water filter housing.
NOTICE
Check the condition of the O-rings and replace if needed. Apply water or silicon
grease to the O-rings before installation.
1 Install the water filter in the correct location.
a
b
a
c
a
EPRA08~12EAV3+W1 + ETBH/X12EF6V+9W