SECTION 7: SET-UP GUIDE FOR BOTTLE FILLER ELECTRONICS

Factory Default Program Settings Are:
a.
Units - Gallons
b.
Unfiltered Unit
c.
Filter Capacity = 4750 gal (18000L) for a VersaFilter III
For Hands-Free Aqua Pointe Models: Remove lower front panel (if applicable) or lift out lower edge of upper
panel to reach remote push button.
Display
000000000
BOTTLES REUSED
(Home Screen)
LTR/GAL
GAL[LTR]
UNFILT/FILT?
UNFILTERED UNIT
[FILTERED UNIT]
SELECT RATE
1.0 GPM UNIT
[3.8 LPM UNI]
SELECT RATE
1.0 GPM UNIT
[3.8 LPM UNIT]
RESET 0000000000
GALLON COUNT?
[LTR COUNT?]
FILT CAPAC
OF 4750 GAL
[18000 LTR]
3 SEC RULE?
3 sec
[0.5L]
RESET 000000000
BOT COUNT?
BOT FILLER
SET TIME: 20 S
RUN CAL
AGAIN?
Depress button for 3 seconds to enter into the following menu settings and make changes.
Note: at any time it will exit menu and save settings when idle for 10 seconds (no button
press) and revert back to Home Screen.
Depress button 3 seconds to change from Gallons to Liters, or momentarily press to
advance to the next menu.
Depress button 3 seconds to change from Unfiltered to Filtered unit, or momentarily press
to advance to next menu.
To change flow rate, momentarily depress button to change whole gallon digit. Hold
button 3 seconds to advance to TENTHS of gallon digit. Depress momentarily to change
the digit. Hold button 3 seconds to advance to the next menu.
To change flow rate, momentarily depress button to change whole gallon digit. Hold
button 3 seconds to advance to TENTHS of a gallon digit. Depress momentarily to change
the digit. Hold button 3 seconds to advance to next menu.
Depress button for 3 seconds to reset Gallon or Liter count, or momentarily press to
advance to next menu.
Depress button for 3 seconds to change filter capacity to 1250 GAL [5000 LTR] for
VersaFilter I.
Depress button for 3 seconds to change filter capacity to 3000 GAL [11000 LTR] for
VersaFilter II
Depress button for 3 seconds to switch from 3 sec rule to 0.5L bottle, or momentarily press
to advance to next menu.
Depress button for 3 seconds to switch from 3 sec rule to 0.5L bottle, or momentarily press
to advance to next menu. (The 3 sec rule increases the bottle count based on a 3 second
dispense.
Depress button for 3 seconds to change maximum dispense time to 10, 20 or 30 seconds, or
momentary press to advance to next menu.
Depress button 3 seconds to run calibration again, or momentarily press to advance to
next menu.
d.
Bottle Count = 0.5L (1 Bottle)
e.
Flow Rate = 1.0GPM
f.
20 sec. Maximum Dispense Time