Page 1
User Guide Modular Series Electronic Bottle Fillers: MWEBQ, MW8EBQ, MW12EBQ, MWSMEBQ, MWSM8EBQ, MWSM12EBQ, M8EBQ, M12EBQ, MF2EBQ, MW8F2EBQ, MW12F2EBQ, MWSMF2EBQ, MWSM8F2EBQ, MWSM12F2EBQ, M8F2EBQ, M12F2EBQ Please read these instructions before installing this product...
Page 2
OASIS AQUA POINTE® ELECTRONIC BOTTLE FILLER INSTRUCTIONS 1. INSPECTION Inspect the cartons and various components for evidence of rough handling and concealed damage. Damage claims should be filed with the carrier. 2. INSTALLATION, PLUMBING & ELECTRICAL CONNECTIONS a) Note: The following states require a licensed plumber to install cooler; AR, GA, MA, MI, OK, RI, SC, SD, TX, VT and WI.
Page 3
3. OVERLOAD PROTECTION (systems with chiller) The compressor motor is equipped with an automatic reset protector which will disconnect the motor from the line in case of overload. 4. LUBRICATION (systems with chiller) This unit is equipped with a hermetically sealed compressor. No additional lubrication is required. The fan motor installed on this unit seldom needs oiling.
IMPORTANT REQUIREMENTS CAUTION: Ensure bottle filler is properly grounded. It is required to attach the long green ground wire to the frame assembly junction box in order for the unit to function properly. Refer to the steps described in Step 4 on Page 12. CAUTION: Do not activate bottle filler electric eye sensor without running water through the UV-C module.
IMPORTANT REQUIREMENTS LED Indicator Display LED Color Display Condition Action Ensure water supply is ON. If initial start-up: Activate the bottle “UVC OFF- TURN While dispensing, UVC ORANGE filler to dispense water. ON WATER SUPPLY” temperature is too high. LED will turn BLUE when water flows.
Page 6
OASIS MODULAR HANDS-FREE QUASAR VERSAFILLER (WITH OR WITHOUT VERSAFILTER III AND REMEDI FILTER) MODELS: MWEBQ, MW8EBQ, MWF2EBQ, MW8F2EBQ, MW12F2EBQ...
Page 7
OASIS MODULAR HANDS-FREE QUASAR VERSAFILLER (WITH OR WITHOUT VERSAFILTER II AND REMEDI FILTER) MODELS: M8EBQ, M12EBQ, M8F2EBQ, M12F2EBQ...
Page 8
OASIS MODULAR HANDS-FREE QUASAR VERSAFILLER (WITH OR WITHOUT VERSAFILTER III AND REMEDI FILTER) MODELS: MWSMEBQ, MWSM8EBQ, MWSM12EBQ, MWSMF2EBQ, MWSM8F2EBQ, MWSM12F2EBQ...
SECTION 1: BOTTLE FILLER ASSEMBLY WITH CHILLER OVERVIEW Wall mounting frame secures into wall with face flush to the finished wall. Optional VersaFilter III Upper front panel mounts to frame with bottom screws. Secure cradle mounting angles to frame flange using screws provided.
Junction P-Trap Install snap bushings. (Not Included) Optional Filter Location Less Chiller STEP 2: MWEBQ (WITHOUT CHILLER ONLY) Solenoid Valve Out Install provided ball valve and 3/8” O.D. copper tube to building water supply. Install tubing as shown before mounting the panel assembly.
Page 11
STEP 3A: FILTER INSTALLATION (WITHOUT CHILLER) Mount Filter Clip To Frame. Install Provided Stem Elbows Cut water line shown from solenoid valve out to bottle filler delivery fitting. Squeeze end of tube back to round shape as needed. Connect tube from solenoid valve out to filter in. Connect filter out to filler delivery fitting.
Page 12
STEP 3B: FILTER INSTALLATION (WITHOUT CHILLER) Optional In-Line Filter UV-C LED Optional Versafilter III Solenoid Valve Inlet Ball Valve Assy. with Strainer Plumbing rough-in and wall opening should be prepared as shown in the rough-in drawing. This drinking water cooler is designed to be operated at a water supply line pressure of up to 100 PSI (690 kPa).
SECTION 3: MW8EBQ, MW12EBQ STEP 1 : FILTER INSTALLATION (WITH CHILLER) Attach cradle to frame per rough-in drawing. (Screws Provided - 4) Place chiller in frame. Install 1/4” union fittings on chiller inlet and outlet. Connect water line from bottle filler solenoid valve out to chiller water in. Connect chiller water out to bottle filler delivery fitting.
Page 14
STEP 2A: FILTER INSTALLATION (WITH CHILLER) Screw filter clip to the chiller in the location shown below. (Screw provided) Install the 1/4” stem elbows (provided) in filter Inlet and outlet. Place the filter in clip as shown. STEP 2B: INSTALLATION Cut water line from buttle filler solenoid valve out to connect to filter in.
Page 15
STEP 3: FILTER INSTALLATION (WITH CHILLER) UV-C LED Solenoid Valve Optional Optional In-Line Versafilter III Filter Inlet Ball Valve Assy. with Strainer Chiller Plumbing rough-in and wall opening should be prepared as shown in the rough-in drawing. This drinking water cooler is designed to be operated at a water supply line pressure of up to 100 PSI (690 kPa).
SECTION 4: M8EBQ/M12EBQ CHILLER AND FOUNTAIN CONNECTIONS Install Chiller in Frame. Remove reducer fitting and copper tube from fountain water line. Install provided Install 1/4” Union on Chiller inlet. 1/4” union. Connect 1/4” Union Tee to Chiller Outlet. Determine length of tube needed to connect bottle filler solenoid “out”...
SECTION 5: TRIM BEZEL INSTALLATION (FOR SURFACE MOUNT MODELS) Install frame assembly to a flat surface. Use appropriate fastening hardware (not included). Refer to rough-in for correct installation height. Remove Bottom Plate from Trim Bezel (4 screws) Install Trim Bezel around the Frame Assembly and replace Bottom Plate with screws. Place drip tray in frame but do NOT fasten in place.
SECTION 7: SET-UP GUIDE FOR BOTTLE FILLER ELECTRONICS Factory Default Program Settings Are: Units - Gallons Bottle Count = 0.5L (1 Bottle) Unfiltered Unit Flow Rate = 1.0GPM Filter Capacity = 4750 gal (18000L) for a VersaFilter III 20 sec. Maximum Dispense Time For Hands-Free Aqua Pointe Models: Remove lower front panel (if applicable) or lift out lower edge of upper panel to reach remote push button.