Download Print this page

S&P DOMEO 210 RD Manual page 20

Hide thumbs Also See for DOMEO 210 RD:

Advertisement

5.2 - During use
The remote control allows the user to:
• Activate the boost for ½ hour.
• Return manually to the minimum airflow
• Put DOMEO in holidays mode
• Manually switch on the by-pass mode
• Reset filters alarm
Low Airflow
+
Holidays mode
The remote control put on the "energy saving" mode after 10 seconds, switching off all LEDS.
Minimum airflow (Trickle): (Flashing green LED)
When the DOMEO is in Boost mode, it is possible, by pressing the left button,
to return to the minimum airflow before ½ hour has elapsed
Boost: (Flashing green LED)
A button that enables the boost airflow for 30 minutes to be selected in ½-hour steps.
By-pass: (Flashing green LED)
On having avoided the heat exchanger, the 100% by-pass system of the
DOMEO allows the introduction of fresh air in the night without being warmed
by the warm air accumulated in the house during the day.
This system works automatically with this conditions:
The specific airflow can be adjusted to optimize the cooling nigh time or free cooling (see
paragraph 5.1.a 3)
If you want , you can manually switch to by-pass mode by pressing the by-pass button.
During this operation it is possible to cancel this function by pressing the by-pass key
once more.
Holidays mode: (Flashing red LED)
Press the left key for 3 seconds to activate Holidays mode (50% of minimum airflow). It is
possible to return to normal mode by pressing the same key once more.
Filters alarm: (red LED):
DOMEO alerts when the filter timer has arrived to the limit lightning a red LED on the
right hand key. The factory setting is 9 months after commissioning or changing the
filters. You must change the filters.
If the 9 month interval is not ideal for the configuration or use of your installation (filters
too dirty or clean) it is possible to adjust this setting from 6 to 15 months (in 3 monthly
steps – see paragraph 5-1-b)
Once changes have been made push the button 3 seconds to deactivate the
20
Kitchen Boost
Pushing on one of the keys the function LED activated lights.
- Tº inner >1+ Tº outer and Tº inner > 24ºC and Tº outer> 12ºC,
alarm and reset the timer.
By-pass

Advertisement

loading

This manual is also suitable for:

Domeo 210 rd sc