Air to Water Heat Pump (Split integrated DHW type)
Line
Function
Diagnostics consumers
8700
U
Outside temperature
8701
U
Outside temp min
Reset ? (no, yes)
8702
U
Outside temp max
Reset ? (no, yes)
8703
I
Outside temp attenuated
Reset ? (no, yes)
This is the average of the outside temperature over a 24-hour period.
This value is used for automatic Summer / Winter switchover (line 730).
8704
I
Outside temp composite
The mixed outside temperature is a combination of the current outside temperature and the average outside temperature
calculated by the regulator. This value is used for calculating the initial temperature.
8730
I
Heating circuit pump, circuit 1
8731
I
Mixer valve HC1 open
8732
I
Mixer valve HC1 closed
8740
U
Room temperature 1
Room setting 1
8743
U
Flow temperature 1
Flow temperature setpoint 1
8756
U
Cooling flow temperature 1
Cooling flow temperature setpoint 1
8760
I
Heating circuit pump, circuit 2
8770
I
Room temperature 2
Room setpoint 2
8773
U
Flow temperature 2
Flow temperature setpoint 2
8820
I
DHW pump
I
8821
El imm heater DHW
8830
U
DHW (domestic hot water) temperature
DHW temperature setpoint
8840
S
Hours run DHW pump
S
8841
Start counter DHW pump
8842
S
Hours run electric DHW
8843
S
Start counter electric DHW
8900
U
Swimming pool temperature
Swimming pool temperature setpoint
8950
I
Common flow temperature
Common flow temperature setpoint
8957
I
Common flow setpoint, refrigeration
I
8980
Not used
8981
I
Not used
- 54 -
Setting range
or display
-50... 50 °C
-50... 50 °C
-50... 50 °C
-50... 50 °C
-50... 50 °C
Off, On
Off, On
Off, On
0
50 °C
0
140 °C
0
140 °C
Off, On
0
50 °C
0
140 °C
Off, On
Off, On
0
140 °C
0... 2730 h
0
199999
0... 2730 h
0
65535
0
140 °C
0
140 °C
0
140 °C
Installation and operating manual "1585 - EN"
Setting
Basic
increment
setting
--
--
--
--
--
Off
Off
Off
--
20 °C
--
--
--
--
Off
--
20 °C
--
--
Off
Off
--
50 °C
--
--
--
--
--
22 °C
--
--
--