Document n° 1534-1 ~ 13/06/2012 Air to Water Heat Pump Split system Operation manual intended for professionals and end users. To be saved for future consultation Fujitsu General (Euro) GmbH Werftstrasse 20 40549 Düsseldorf - Germany Subject to modifications without notice.
Air to Water Heat Pump Packing list Heat Pump Outdoor Unit Hydraulic Unit Model Reference Reference Waterstage High Power 11 single phase WO*G112LCT WS*G140DC6 Waterstage High Power 14 single phase WO*G140LCT Waterstage High Power 11 3-phase WO*K112LCT Waterstage High Power 14 3-phase...
Air to Water Heat Pump 1 Instructions to be read before using the equipment Please comply with the following instructions in order to avoid any risk of injury or inappropriate use of the appliance. Safety instructions 1.1.1 Start-up 1.1.3 Maintenance "...
Air to Water Heat Pump Precautions and warnings regarding your installation. 1.2.1 The outdoor unit 1.2.4 The radiators The outdoor unit contains the equipment for capturing To ensure the function of the regulation with room energy from the ambient air.
Air to Water Heat Pump 2 Overall view of the installation Your heat pump has been configured by your installer. It is composed of the following main elements: - The outdoor unit is positioned, as its name indicates, outside your dwelling and extracts energy from the outside air.
Air to Water Heat Pump 3 Operation of the installation User interface, Remote control (option) and Room thermostat (option) User interface Auto Auto °C Remote control (option) Room thermostat (option) figure 2 - Operation manual "1534 - EN" - 6 -...
Page 7
Air to Water Heat Pump Ref. Functions - Definitions Selecting of the DHW operating mode - If the installation is fitted with a DHW tank. (Domestic hot water). - On: Production of DHW according to the time program. - Off: Preparing the domestic hot water for stopping with the anti-frost function active.
Air to Water Heat Pump Description of the display Xxxxxxxxxxxxxxxxxxxxxxxxxxx Xxxxxxxxxxxxxxxxxxxxxxxxxxx Xxxxxxxxxxxxxxxxxxxxxxxxxxx figure 3 - Symbols Definitions - Heating mode active with reference to the heating circuit. - Heating in comfort mode. - Heating in reduced mode. - Heating in "standby" mode (freeze protection).
Air to Water Heat Pump Appliance start up Quick start-up Once your installer has started your installation for the • The installation and 1st start up of the appliance first time: must be done by a qualified installer. That person will also give you instructions on starting and running the •...
Air to Water Heat Pump Setting the time Keys Display example Description Basic display AUTO If the basic display is not shown, press ESC to return to it Room temperature Press OK to confirm. AUTO Turn the knob Select menu hour and date...
Air to Water Heat Pump Structure of the "End user" control menu Basic Brief display press End user Commissioning Engineer Time of day and date Hours / minutes Hours 1 ...24 h Day / Month Minutes 0...60 min Year Operator section Language English, German...
Air to Water Heat Pump Parametering the setting 3.7.1 General 3.7.2 Setting parameters Only the parameters accessible to levels: With the screen on basic display. End user - Press OK. Are described in this document. Once in "End user" level.
Page 13
Air to Water Heat Pump Line Function Setting range Setting Basic or display increment setting Time program heating, circuit 1 Pre-selection (Day / Week) Mon-Sun, Mon-Fri, Sat-Sun, Mon-Sun Monday, Tuesday, … 1st phase On (start) 00:00... --:-- 10 min 6:00 1st phase Off (end) 00:00...
Page 14
Air to Water Heat Pump Line Function Setting range Setting Basic or display increment setting Time program 5 / Cooling If the installation is fitted with the cooling kit (Only with the cooling kit option). Pre-selection (Day / Week) Mon-Sun, Mon-Fri, Sat-Sun, Mon-Sun Monday, Tuesday, …...
Page 15
Air to Water Heat Pump Line Function Setting range Setting Basic or display increment setting Domestic hot water If the installation is fitted with the DHW kit (Only with the DHW kit option). 1610 Nominal setpoint Reduced setpoint (line 1612)…...
Air to Water Heat Pump Information display Various data can be displayed by pressing the info - Various data (see below). button. Designation Line Depending on the type of unit, configuration and Floor drying current setpoint . operating state, some of the info lines listed below may Current drying day.
Air to Water Heat Pump 3.10 Operation of the DHW system The key enables you to switch the DHW (domestic hot water) mode on and off. The selection is shown by a bar, which appears under the corresponding symbol. Manual activation: Hold down the DHW key for 3 seconds (Switch from "reduced"...
Air to Water Heat Pump 4 Maintenance In order to insure your appliance operates correctly for many years, the maintenance operations described below are required at the start of each heating season. Generally, these are performed as part of a service contract.
Page 19
Air to Water Heat Pump Operation manual "1534 - EN" - 19 -...
Page 20
This appliance is marked with this symbol. This means that electrical and electronic products shall not be mixed with general household waste. European Community countries(*), Norway, Iceland and Liechtenstein should have a dedicated collection system for these products. Do not try to dismantle the system yourself as this could have harmful effects on your health and on the environment. The dismantling and treatment of refrigerant, oil and other parts must be done by a qualified installer in accordance with relevant local and national regulations.