Sanyo SAP-K71GH Technical & Service Manual page 9

Table of Contents

Advertisement

2-2-2. Outdoor Unit
Outdoor Unit
SAP – C71GH
Controller PCB
Compressor
Type
Compressor model
Nominal output
Compressor oil ... Amount
Coil resistance (Ambient temp. 25°C)
Safety devices
Type
Overload relay
Operating temp.
Operating amp.(Ambient temp. 25°C)
Run capacitor
Crank case heater
Fan & Fan Motor
Type
Q'ty ... Dia.
Fan motor model ... Q'ty
No. of poles ... rpm (230 V, High)
Nominal output
Coil resistance (Ambient temp. 20°C)
Safety devices
Type
Operating temp.
Run capacitor
Heat Exch. Coil
Coil
Rows
Fin pitch
Face area
External Finish
W
cc
Open
°C
Close
°C
Trip in 6 to 16 sec. at 13.8A
µF
VAC
W
Open
°C
Close
°C
µF
VAC
mm
m
2
6
POW-C96GH-S
Rotary (Hermetic)
C-1R71H5V 80688845-S
700
SUNISO 4GSD-T ... 320
C–R : 4.57
C–S : 6.90
External(OLR A)
MRA99802-9201
145±5
69±11
20.0
400
Propeller
1 ... ø370
UE6-21AH5PC-S ... 1
6 ... 760
20
BRN-WHT : 338.3
PNK-WHT : 389.7
IInternal fuse
145 ± 2
1.5
440
Aluminum plate fin / Copper tube
1
1.2
0.259
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
External(OLR T)
CS-7C115
115±3
95±5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sap-c71ghSap-k91ghSap-c91gh