Feature Descriptions; Menu #1 - Directed Electronics Auto mate 552 Installation Manual

Table of Contents

Advertisement

feature descriptions

The features of the system are described below. Features that have additional settings that can be selected only
when programming with the PC interface or Bitwriter are indicated by the following icon:

menu #1

1-1 ACTIVE/PASSIVE ARMING: When active arming is selected, the starter kill will arm (if connected) only when
the transmitter is used. When set to passive arming, the starter kill will arm (if connected) 30 seconds after the
ignition key is turned off.
1-2 CHIRPS ON/OFF: This feature controls the chirps that confirm arming and disarming of the system. A siren
or horn must be connected to the H1/10 BROWN wire.
1-3 IGNITION CONTROLLED DOOR LOCKS ON/OFF: When turned on, the doors will lock three seconds after the
ignition is turned on and unlock when the ignition is turned off.
1-4 ACTIVE/PASSIVE LOCKING: If passive arming is selected in Menu One, Feature 1-1, then the system can be
programmed to either lock the doors when passive arming occurs, or only lock the doors when the system is armed
with a transmitter. Active locking means the doors will not lock when the system passively arms. Passive locking
means that the doors will lock whenever the system passively arms the starter kill (if connected).
1-5 DOOR LOCK PULSE DURATION: Some European vehicles, such as Mercedes-Benz and Audi, require longer lock
and unlock pulses to operate the vacuum pump. Programming the system to provide 3.5 second pulses will accom-
modate the door lock interface in these vehicles. The default setting is 0.8 second door lock pulses.
1-6 DOUBLE PULSE UNLOCK OFF/ON: Some vehicles require two pulses on a single wire to unlock the doors.
When the double pulse unlock feature is turned on, the BLUE H2/C wire will supply two negative pulses instead
of a single pulse. At the same time, the GREEN H2/A wire will supply two positive pulses instead of a single pulse.
This makes it possible to directly interface with double pulse vehicles without any extra parts.
1-7 CHANNEL TWO OUTPUT:
I In the delayed validity default setting the Channel 2 output will output a negative (-) signal after the
Channel 2 button is pressed for more than 1.5 seconds and will continue until the button is released.
I Selecting instant validity will output a negative signal from the Channel 2 output immediately when the
Channel 2 button is pressed and will continue until the button is released.
I The latched output selection will output a negative signal as soon as the Channel 2 button is pressed and
will continue until the button is pressed again.
I The latched/reset with ignition output selection operates just like the latched output but will reset or stop
when the ignition is turned on.