Installing The Air Cleaner Cover; Installing The Discharge Tunnel Plug - Toro Recyler 22038 Operator's Manual

Proline 53 cm walk power lawn mower
Table of Contents

Advertisement

4. Hook the fuel tank retainer onto the rear of the fuel
tank, and slide the end of the retainer into the hole in
the fuel tank bracket (Fig. 4).
5. Secure the retainer to the tank bracket with a locknut
(Fig. 4). Do not overtighten the locknut.
6. Remove the red cap from the end of the fuel line and
from the end of the elbow fitting on the fuel tank
(Fig. 5).
Figure 5
1. Fuel line clamp
2. Fuel line
7. Slide the end of the fuel line onto the elbow fitting
(Fig. 5).
8. Secure the fuel line in place with the fuel line clamp
(Fig. 5).

Installing the Air Cleaner Cover

1. Insert the bottom tabs of the air cleaner cover into the
slots (Fig. 6).
Figure 6
1. Slots
2. Tabs
2. Rotate the cover upward and snap it into place (Fig. 6).
All manuals and user guides at all-guides.com
m-2943
3. Elbow fitting
m-196
3. Cover
4. Spark-plug wire
Installing the Discharge Tunnel
Plug
1. Open the discharge door by pulling forward on the
handle and moving it rearward (Fig. 7). Hold the
discharge door handle to prevent the spring-loaded
door from closing while you insert the plug.
Figure 7
1. Discharge door handle
2. Since the plug is slightly wider than the discharge
tunnel opening, rotate the plug clockwise slightly
while inserting it (Fig. 7).
Note: Ensure that the arrow on the plug decal points
upward.
3. Push the plug all the way in until the spring clip on the
bottom of the plug clicks into place, locking the plug
securely into the discharge tunnel (Fig. 8).
Figure 8
1. Spring clip
4. Release the discharge door handle to lock the top of
the plug.
8
1
2
m–262
2. Plug rotated clockwise
1
m–275

Advertisement

Table of Contents
loading

This manual is also suitable for:

210000001

Table of Contents