Figure 6. Motor Grease Maintenance Conditions
Grease Fitting and Grease Relief
Motor Nameplate
Apply grease as follows:
1. Operate the machine or use manual functions to operate the motor until it is warm.
2. Remove power from the machine.
3. If the motor has grease drain plugs, remove them. See the caution statement above..
4. Add grease EM
(Table 8: Lubricant Identification, page 20
motor with the nameplate in the above figure operates at 60 Hz, the specified grease quantity
for each grease fitting is 0.65 fl oz (18.4 mL).
22
Grease Fitting and Grease Drain
Grease Fittings, No Reliefs or Drains
Legend
1...
Grease fitting
2...
Grease relief. Do not remove.
3...
Grease drain plug. Remove first.
4...
RPM (motor speed). This example is 1465 RPM
at 50 Hz and 1765 RPM at 60 Hz.
5...
NEMA (IEC) frame size. Example: 256T