Section 4 − Specifications; Serial Number And Rating Label Locations; Weld, Power, And Engine Specifications; Dimensions, Weights, And Operating Angles - Miller Kubota Big Blue 600 Pro Owner's Manual

Hide thumbs Also See for Kubota Big Blue 600 Pro:
Table of Contents

Advertisement

4-1. Serial Number And Rating Label Locations

The serial number and rating information for this product is located on the right side. Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.

4-2. Weld, Power, And Engine Specifications

.
This equipment will deliver rated output at an ambient air temperature up to 1045F (405C).
Weld
Welding
Output
Welding
Mode
Range
43 Volts DC,
CC/DC
20 − 600 A
40% Duty Cycle
42 Volts DC,
60% Duty Cycle
CV/DC
13 − 50 V
40 Volts DC,
100% Duty Cycle
* With Low OCV switch (Voltage Reducing Device, VRD) enabled, open−circuit voltage is 13 to 15 volts DC until arc initiation.

4-3. Dimensions, Weights, And Operating Angles

Dimensions
54 in. (1372 mm)
Height
(to top of exhaust)
28.5 in. (724 mm)
(mtg. brackets turned in)
Width
30.75 in. (781 mm)
(mtg. brackets turned out)
Depth
69.5 in. (1765 mm)
A
69.5 in. (1765 mm)
B*
57.9 in. (1470 mm)
C*
46.375 in. (1178 mm)
D*
11.5625 in. (294 mm)
E
27.5 in. (699 mm)
F
1 in. (25 mm)
G
29.8125 in. (757 mm)
9/16 in. (14 mm) Dia.
H
4 Holes
*
With mounting brackets in center
position. Dimensions vary with
location of mounting brackets.
Weight
No fuel: 1750 lb (793.8 kg)
Lifting Eye Weight Rating:
2500 lb (1134 kg) Maximum

4-4. Environmental Specifications

A. IP Rating
This equipment is designed for outdoor use. It may be stored, but is not intended to be used for welding outside during precipitation unless
.
Complete Parts List available at www.MillerWelds.com
SECTION 4 − SPECIFICATIONS
Maximum
Rated
Open-Circuit
Voltage
Output
(Nominal)
575 A,
92*
550 A,
500 A
92*
A
B
C
D
Generator Power Rating
Independent of Weld Output
Single-Phase,
4 kVA/kW, 34/17 A,
120/240 V AC, 50/60 Hz
3-Phase Generator
(In Addition To Standard
4 kVA/kW Generator)
Single-Phase/Three-Phase,
12/20 kVA/kW, 50/48 A,
120/240 VAC, 50/60 Hz
G
!
!
H
20
20
F
E
802 161-A
IP Rating
IP23S
sheltered.
Fuel Tank
Engine
Kubota V2403
Liquid-Cooled,
Four-Cylinder,
48.9 HP Diesel Engine
Tier 4 Final Compliant
Do not exceed tilt angles or engine could
be damaged or unit could tip.
Do not move or operate unit where it could
tip.
°
°
OM-272375 Page 19
Capacity
25 gal
(95 L)
°
30
°
30
907 695
IP23S 2014−06

Advertisement

Table of Contents
loading