Graco 970086 Instructions-Parts List Manual page 10

55 gallon, 65:1 quiet king module supply units
Table of Contents

Advertisement

Low–Level Shutoff Setup (Model 970088)
Setup the low–level shutoff as shown in Fig. 4. See
also manual 310294.
During system operation, as the ram approaches the
drum bottom, the top of the ram contacts the limit
valve. The switch shuts off the air to the air motor.
KEY
A
3–Way Pilot Valve
B
Air Limit Valve
C
Limit Valve Bracket
Fig. 4
10
310364
System Setup
Low–Level Shutoff Setup (Model 970088)
A
NOTE: The position of the air limit valve (B) on the
ram determines when the ram air motor is turned on
and off. During operation, this position can be adjusted
as desired. See Fig. 4.
B
C
8890A