C Check of indoor P.C. board and indoor fan motor
Turn OFF the power supply.
Remove the indoor fan motor connector
CN211 and the vane motor connector
CN151 from the indoor electronic control
P.C. board and turn ON the power supply.
Does the unit operate with the remote
controller?
Does OPERATION INDICATOR lamp light
up by pressing the emergency operation
switch?
No
Turn OFF the power supply.
Check both "parts side" and "pattern
side" of the indoor power P.C. board
visually.
Measure the resistance of resistor
(R111) (MSZ-AY25/35/42VGK, MSZ-
AY25/35/42VGKP)/reactor (L112)
(MSZ-AY50VGK, MSZ-AY50VGKP) on
the indoor power P.C. board.
Terminal
P.C. board
Indoor electronic
control P.C. board
Fuse (F11)
LD201(T)
Varistor
(NR11)
OBH930
Measure the resistance between
CN211
and
connector.
Measure the resistance of the vane
motor coil.
Yes
Refer to 10-5.
Replace the varistor (NR11)
and fuse (F11). *3
Are the varistor (NR11)
burnt and the fuse (F11)
blown?
Be sure to check both the fuse
and the varistor in any case.
Is the fuse (F11) blown
only?
Measure the resistance between
CN211
(+) and
motor connector. *1, *2
Is the resistance 1MΩ or more?
Replace the fuse (F11). *3
Replace the indoor electronic control P.C. board.
LD201(M)
R111
L112
GND
of the indoor fan motor
Yes
No
No
Yes
*1. The fan motor connector's
is black.
*2. Connect "+" of the multimeter to fan motor connector's
lead wire, and "-" to
(-) of indoor fan
resistance cannot be measured properly.
*3. Please replace the fuse after removing the indoor
power P.C. board from the electrical box.
Replace the fuse (F11) and the
No
indoor fan motor. *3
Yes
Is the resistance of resistor (R111)
(MSZ-AY25/35/42VGK,MSZ-
AY25/35/42VGKP) approximately
3.9Ω/ reactor (L112) (MSZ-
AY50VGK, MSZ-AY50VGKP)
approximately 4.3Ω?
Yes
35
Short circuit:
Replace the indoor fan motor.
Short circuit:
Replace the vane motor and the indoor
electronic control P.C. board.
lead wire is red, whereas
lead wire, otherwise the
Replace the indoor electronic con-
trol P.C. board and the indoor fan
No
motor.