Download Print this page

Gravely Pro-Turn 152 EFI Operator's Manual page 30

Hide thumbs Also See for Pro-Turn 152 EFI:

Advertisement

CHECK PARKING BRAKE
IMPORTANT: Parking brake lever engages
drive wheels with two independent cables. It
is possible for parking brake to engage one
drive wheel only, indicating parking brake
cable on opposite side is out of adjustment.
1. Place unit in service position. See
Service Position on page 23.
2. Bypass transaxles. See Move Unit
Manually on page 22.
3. Push unit forward.
• If unit does not move forward, parking
brake is functioning correctly. Advance
to step 4.
• If unit moves forward easily or if just
one side of unit moves easily, adjust
parking brake. See Adjust Parking
Brake on page 34.
4. Return transaxle bypass levers to
operating position. See Move Unit
Manually on page 22.
5. Return seat to operating position.
CLEAN BATTERY
WARNING: AVOID INJURY.
Battery posts, terminals and
related accessories contain lead
and lead compounds, chemicals
known to the State of California
to cause cancer and
reproductive harm. Wash hands
after handling.
Remove Battery
See Figure 31.
1. Place unit in service position. See
Service Position on page 23.
2. Disconnect the negative cable and then
the positive cable from battery.
3. Remove wing knobs securing hold-down
bracket to battery and remove bracket.
4. Remove battery.
Clean Battery
1. Clean terminals and battery cable ends
with a wire brush.
2. Coat terminals with dielectric grease or
petroleum jelly.
Install Battery
1. Install battery and secure with hold-down
bracket and wing knobs.
2. Reconnect positive cable and then the
negative cable.
3. Place boot over positive terminal.
4. Return seat to operating position.
CHARGE BATTERY
Check battery with a voltmeter. If battery is
less than 11 volts, charge battery.
NOTICE: DO NOT fast charge. Charging at a
higher rate damages or destroys battery.
ONLY use an automatic charger designed for
use with your battery.
NOTICE: Always follow information provided
on battery by battery manufacturer. Contact
battery manufacturer for details regarding
charging.
1. Remove battery from unit. See Remove
Battery on page 28.
2. Place battery on bench in a well-
ventilated area.
3. Connect positive lead of charger to
positive terminal.
4. Connect negative lead of charger to
negative terminal.
EN - 28
Figure 31

Advertisement

loading