Technical Specifications
This section provides important technical specifications related to the device.
5.1
Power Supply Specifications
Note
When determining cable lengths, make sure the minimum input voltage for the pow-
er supply is provided at the power source.
Hazardous Environments
Power Sup-
ply Type
a
(T) denotes time-delay fuse.
b
Power consumption varies based on configuration.
Non-Hazardous Environments
Power Sup-
ply Type
a
(T) denotes time-delay fuse.
b
Power consumption may vary based on configuration.
RUGGEDCOM RS900F
Installation Manual, 02/2020, C79000-G8976-1350-04
All manuals and user guides at all-guides.com
Input Range
Minimum
HI
125 VDC
100 VAC
24
12 VDC
48
37 VDC
Input Voltage
Minimum
HI
88 VDC
85 VAC
24
10 VDC
48
37 VDC
Internal
Fuse Rating
Maximum
250 VDC
3.15 A(T)
240 VAC
3.15 A(T)
24 VDC
3.15 A(T)
72 VDC
3.15 A(T)
Internal
Fuse Rating
Maximum
300 VDC
3.15 A(T)
264 VAC
3.15 A(T)
36 VDC
3.15 A(T)
72 VDC
3.15 A(T)
Isolation
Maximum
a
Power Con-
sumption
4 kVAC
10 W
4 kVAC
10 W
1.5 kVDC
10 W
1.5 kVDC
10 W
Isolation
Maximum
a
Power Con-
sumption
4 kVAC
10 W
5.5 kVDC
10 W
1.5 kVDC
10 W
1.5 kVDC
10 W
5
b
b
25