Some LP tanks have differing top collar assemblies. (The top collar is the metal protective
ring around the valve.) One series of tanks mount with the valve facing front (1). The other
tanks mount with the valve facing away from the fuel scale (2). Weber recommends
Manchester or Worthington tanks with a 47.6 lb water capacity. Other tanks may be
acceptable for use with the appliance provided they are compatible with the appliance
retention means (see illustrations).
The LP tank is installed inside the tank enclosure, on the tank scale (left side).
A) Loosen tank lock wing nut. Swing tank lock up (3).
B) Turn the LP tank so the opening of the valve is either to the front or side of the
WEBER gas grill.
C) Lift tank up into position on the tank scale (4).
D) Swing the tank lock down. Tighten the wing nut.
Connect The Hose To The Tank
A) Remove the plastic dust cover from the valve.
B) Screw the regulator coupling onto the tank valve, clockwise, or to the right. Hand-
tighten only (5).
Note: This connection tightens clockwise and will not allow gas to flow unless the connection
is tight. The connection requires tightening by hand only.
m WARNING: Do not use a wrench to tighten the connection. Using
a wrench could damage the regulator coupling and could cause
a leak.
10