Download Print this page

True Induction TI-1G Manual page 14

Gas combo cooktop

Advertisement

I. Installation Continued...
Leak Test Continued...
Install the male 1/2" flare union adapter to the 1/2" NPT internal thread at inlet of regulator.
Use a backup wrench on the regulator fitting to avoid damage.
When installing the range from the front, remove the 90° elbow for easier installation.
Install the male 1/2" or 3/4" flare union adapter to the NPT internal thread of the manual
shut-off valve, taking care to back-up the shut-off valve to keep it from turning.
Connect the flexible metal appliance connector to the adapter on the cooktop. Position the
cooktop to permit connection at the shut-off valve.
When all connections have been made, make sure all cooktop controls are in the off position
and turn on the main gas supply valve. Use a liquid leak detector at all joints and connec-
tions to check for leaks in the system.
Gas flow to the burners is adjusted by turning the knobs which control the valves. Turning the
knob so that the indicator line points to the symbols printed on the panel achieves the following
functions:
When the knob is rotated to the maximum position it will permit rapid boiling of liquids,
whereas the minimum position allows the simmer warming of food or maintaining boiling
conditions of liquids.
To reduce the gas flow to minimum, rotate the knob counter-clockwise to the LOW Position.
Other intermediate operating adjustments can be achieved by positioning the indicator be-
tween the HI and LOW positions, and never between the HI and OFF position.
When the range is not being used, set the gas knobs to their OFF positions and also close
the gas shut-off valve placed on the main gas supply line.