21.4 Installation below a worktop
Observe the installation dimensions and the installation
instructions when installing below a worktop.
¡ To ventilate the appliance, the intermediate floor
must have a ventilation cut-out.
¡ In combination with induction hobs, the gap
between the worktop and appliance must not be
sealed using additional strips.
¡ The worktop must be secured to the built-in unit.
¡ Observe any available installation instructions for the
hob.
21.5 Corner installation
Observe the installation dimensions and the installation
instructions when installing in a corner.
¡ To ensure that the appliance door can be opened,
you must take the minimum dimensions into consid-
eration when installing in a corner. The dimension
is dependent on the thickness of the unit front and
the handle.
21.6 Electrical connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
¡ The appliance corresponds to protection class I and
must only be operated with a protective earth con-
nection.
¡ The fuse protection must correspond to the power
rating specified on the appliance's rating plate and
to local regulations.
¡ The appliance must be disconnected from the
power supply whenever installation work is being
carried out.
¡ Contact protection must be guaranteed by the in-
stallation.
Connecting the appliance to the electricity
supply
Note: Only a licensed professional may connect the ap-
pliance. Damage caused by incorrect connection is not
covered under the warranty.
An all-pole isolating switch must be integrated into the
permanent electrical installation according to the install-
ation regulations.
Identify the phase and neutral conductors in the
1.
socket.
The appliance may be damaged if it is not connec-
ted correctly.
2.
Connect the hob in accordance with the connection
diagram.
The yellow/green wire for the safety earth terminal
must be 10 mm longer on the appliance side than
the other wires.
See the rating plate for the voltage.
Connection 3N~ / 2N~: Use a H05VV-F mains
power cable or one with a higher rating.
Connection 1N~: A suitable H07RN-F 3G6 mains
power cable (length 1.5m) is available from the
after-sales service
21.7 Installing the appliance
Slide the appliance in fully and centre it.
1.
Screw the appliance into place.
2.
​ ⁠
Installation instructions en