Chapter 2: Installation
Although this provides a useful alternative method for securing your instrument,
it is only suitable for use in positions where the instrument will not be exposed to
water.
To bracket mount your ST60+ instrument, do so in accordance with the Control
Unit Mounting Bracket Instruction Sheet.

Connections at the instrument

The connections to the ST60+ Club House Wind instrument are shown in the
following illustration.
Cable from Wind Vane
Connections to ST60+ Club House Wind instrument

Power supply connections

CAUTION: Protect the power supply

Ensure that the 12 V power supply for the instrument is
protected by a suitably rated fuse or protective circuit breaker.
The ST60+ Club House Wind instrument requires a 12 V dc power supply capable
of providing at least 2 A and protected by a 0.5 A fuse.
Power cables are available in 2 m and 9 m lengths.
To fit a power cable:
1. Ensure the intended power source is switched off.
2. Run the power cable from the instrument to a suitable 12 V dc power source.
Power supply cable