Electrode Setting; Kna Burner Air Adjustment; Fuel Pressure Adjustment; Removal Of Soot And Heating Coil - Kärcher Trailer HDS Series Operator's Manual

Table of Contents

Advertisement

Electrode Setting

(For EHASR Only)
SR Series Gage
KNA Part Number #8.717-379.0
CAUTION: If white smoke appears from burner
exhaust vent during start-up or operation,
discontinue use and readjust air bands.
ATTENTION : Si de la fumée blanche apparaît du
conduit d'évacuation du brûleur pendant le
démarrage ou le fonctionnement, cesser d'utiliser
et réajuster les bandes d'air.
NOTE: If a flue is installed, have a professional
serviceman adjust your burner for a #1 or #2 smoke
spot on the Bacharach scale.

Fuel Pressure Adjustment

To adjust fuel pressure, First install a pressure gage
into the port just after the pump fuel exit. Turn the
adjusting screw (located at the regulator port)
clockwise to increase, and counterclockwise to
decrease. Do not exceed 200 psi or lower the pressure
below 130 PSI, when checked at the post-pump
pressure port.
The fuel pressure may need to be adjusted due to
altitude. For every 500 ft altitude above sea level, the
boiling point of water goes down 1 °F. At high altitude
environments, this boiling point change may require the
heat input to be lowered so the water input does not
turn to steam earlier than at the factory settings and
activate the pressure sensors and pressure relief
equipment when the unit is operated and much higher
altitudes from factory settings or local dealer site
settings. Check with your dealer before making local
site fuel pressure adjustments.
Also, as ambient temperature changes seasonally, the
fuel temperature in the feed tank and air temperature
inlet can impact fuel flow. In more extreme tempera-
tures, this local-site adjustment may also require
different fuel nozzles for fuel inlet temperatures that are
at seasonal extremes (higher or lower) in locations
where the temperature changes are beyond moderate
temperatures of between 40°F and 90°F. Colder
Karcher HDS 3.5/40 GE MT Operator's Manual 9.807-942.0 - C
temperatures will make for a thicker flow and less fine a
fuel spray while hotter temperatures will make for a
thinner flow a more fine spray with the same nozzle.
Consider alternate nozzle configurations from the
baseline factory-supplied nozzle for operating in such
temperature extremes if performance is not meeting
needs with air band and fuel pressure settings alone.
NOTE: When changing fuel pump, a by-pass plug
must be installed in return line port or fuel pump will
not prime.

Removal of Soot and Heating Coil

In the heating process, fuel residue in the form of soot
deposits may develop on the heating coil and block air
flow which will affect burner combustion. When soot
has been detected on visual observation, the soot on
the coil must be washed off after following the coil
removal steps.
1. Remove the top wrap by unscrewing the four
screws from the sides and lift the top wrap off.
2. Remove Insulation.
3. Remove the two pipe nipples and associated
fittings.
4. Lift the coil out of the outer wrap.
CAUTION: The coil weighs about 80 lbs. Use proper
lifting techniques.
ATTENTION : La bobine pèse environ 80 livres.
Utilisez les bonnes techniques de levage.
5. Clean, repair and replace the coil by reversing the
above steps.
Coil Reinstallation
Reinstall by reversing the above steps 5 through 1.
NOTE: The 12 VDC burner systems can draw as
much as 18 amps. For such motors to run properly,
the battery and engine charging system must be kept
in good condition, and the engine must run fast
enough to adequately charge the battery. Do not
throttle down the engine for any length of time.
Operations