Electrical connection

The cooker hood has a 3G1.5 mains voltage cable and a black plug including grounding. (It is never
permitted to shorten or extend this cable.) Always use a wall socket including grounding, model
10/16A with pin and/or earth connection.
Mains voltage: up to 230 volts
Alternating current: 50/60 Hz
Protection : classe 1
If necessary, the cable should be protected mechanically.
The cooker hood can only be used with an installation that complies with the following regulations:
BelgiUM : A.R.E.I.
Netherlands : NEN 1010
Germany : VDE 0100
France : NF C15-100
Italy : CEI 64.8
Other member states : HD 384.3.32 + 4.41 + 5.52 + 6.61
The user should provide sufficient protection against the consequences of excess current.