  • Page 1 (217) 352-9330 | Click HERE Find the HP NetServer LXr 8500 at our website:...
  • Page 2 HP NetServer LXr 8000 and LXr 8500 Installation Guide Compaq 4000/7000 Racks ® HP Part Number 5967-6670 Printed in September 1999 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
  • Page 4: Table Of Contents

    Attach the New Control Panel Bezel ............... 28 3 Preparing the Rack ..................29 Overview of Rack Preparation................. 29 Determine the HP NetServer Location in the Rack ......... 29 Mark the Installation Holes ................29 Install the Cage Nuts ..................31 Adjust the Slides ....................
  • Page 5 Install the Compaq Rack Front Bezel.............. 40 A Warranty and Support................... 41 Hardware Accessories Limited Warranty ............41 HP Repair and Telephone Support ..............42 Index........................43 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 6: About This Guide

    About This Guide ® This guide tells how to mount an HP NetServer LXr 8000 or 8500 into a Compaq model 4000-series or 7000-series rack enclosure. Refer to the installation guide that came with the HP NetServer for instructions on adding accessories to and configuring the HP NetServer.
  • Page 7 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 8: Introduction

    HP rack enclosures and were not designed for Compaq racks. Complete and mail the post card in the top tray of the HP NetServer to receive the kit that contains the nameplate, front bezel, control panel bezel, and LCD cover optimized for Compaq racks.
  • Page 9: Order Of Installation Operations

    Chapters 2, 3, and 4 to prepare the HP NetServer, prepare the Compaq rack, and install the HP NetServer in the rack. Awaiting Kit: If you want to install the HP NetServer in the Compaq rack before you receive the Compaq rack-optimized kit, refer to Chapters 3 and 4 to prepare the Compaq rack and install the HP NetServer in the rack.
  • Page 10: Compaq Rack Precautions

    3. Prepare Compaq rack (Chapter 3). 3. After the kit is received: extend HP NetServer from rack (Chapter 2). 4. Install HP NetServer in rack (Chapter 4). 4. Remove bezel latch, control panel bezel, and LCD cover (Chapter 2). 5. Install Compaq rack-optimized 5.
  • Page 11 HP NetServer. This feature consists of two "feet" at the front of the base of the enclosure and, if you are installing this HP NetServer in a single rack enclosure, two "feet" each on the left and right sides of the enclosure (see Figure 1-2).
  • Page 12 HP Warranty. Observe the precautions listed in this section to maintain the HP NetServer's reliability. When the HP NetServer LXr 8000 or 8500 is installed in a Compaq rack enclosure, certain requirements must be addressed to assure that the needs of the HP NetServer are met.
  • Page 13: Tools

    Chapter 1 Introduction Tools The following tools are required to install the HP NetServer in a Compaq rack: ® T15 Torx driver Small thin flat-bladed screwdriver Pozidriv or Phillips screwdriver Needle-nose pliers may also be helpful. Terms Terms used in this document are defined in the table below.
  • Page 14: Preparing The Hp Netserver

    The existing LCD cover (metal housing around the LCD) on the front of the HP NetServer is too thick to accommodate the front bezel to be used in the Compaq rack. This chapter describes how to prepare the HP NetServer for the Compaq rack-optimized front bezel.
  • Page 15: Disconnect The Hp Netserver

    If the backlight on the LCD display is on, standby power is still on. If the HP NetServer is already connected, do the following to disconnect it: 1. Log off all users. Back-up files. Follow instructions in your network operating system (NOS) documentation to properly shut down all networking software and applications.
  • Page 16: Extend The Hp Netserver

    Preparing the HP NetServer Extend the HP NetServer If the HP NetServer is already installed in a Compaq rack (without a front bezel), do the following to extend the HP NetServer: 1. Remove the four screws that secure the HP NetServer to the rack columns, as shown in Figure 2-1.
  • Page 17 Chapter 2 Preparing the HP NetServer 2. To extend the HP NetServer from the rack, pull on the handle indicated in Figure 2-2. Handle Figure 2-2. Pull the Handle to Extend the HP NetServer from the Rack CAUTION When the HP NetServer is extended from the rack, do not lean on it or place extra weight on it.
  • Page 18: Remove Bezel Latch

    Preparing the HP NetServer Remove Bezel Latch If a bezel latch is mounted on the right side of the HP NetServer, remove it to avoid interference with the Compaq rack front bezel. To remove the bezel latch, remove the screw indicated in Figure 2-3.
  • Page 19: Remove The Control Panel Bezel

    Preparing the HP NetServer Remove the Control Panel Bezel NOTE Do not remove the original HP rack-optimized control panel bezel until you have received the Compaq rack-optimized control panel bezel. Remove the existing control panel bezel, as shown in Figure 2-4. Push in on the snap latches on the left and right ends of the control panel bezel, and gently pull the control panel bezel away from the HP NetServer.
  • Page 20: Remove The Top Cover, Fan Cover, Fans, And Fan Cage

    Top Cover Figure 2-5. Removing the Entire Top Cover (HP NetServer LXr 8500 Shown) 2. Lift off the top cover, as shown in Figure 2-5. 3. Remove the screw on the front of the fan cover, as shown in Figure 2-6.
  • Page 21 Chapter 2 Preparing the HP NetServer 4. Pull the fan cover forward, and then lift the front of it about 1 inch (3 cm). 5. Push the fan cover backwards, and lift it off. 6. Remove all six fans by pulling them straight up, as shown in Figure 2-7.
  • Page 22 7. Remove the three screws from the front of the fan cage, as shown in Figure 2-8. Figure 2-8. Removing the Fan Cage (HP NetServer LXr 8500 Shown) 8. Remove the two screws from the sides of the chassis, as shown in Figure 2-8.
  • Page 23: Disconnect The Lcd Cables

    Top Flap of Ribbon Cable Connector Processor Tray Figure 2-9. Disconnecting the LCD Cables (HP NetServer LXr 8500 Shown) CAUTION When disconnecting the LCD cables, pull the connector straight back from the socket. This protects the connector pins from being bent.
  • Page 24: Remove The Existing Lcd Cover

    (12 Places) LCD Assembly Detail Figure 2-10. Removing Screws and LCD Assembly (HP NetServer LXr 8500 Shown) 2. Remove the two screws from the sides of the LCD cover as shown in Figure 2-10. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 25 When the LCD assembly is lifted high enough, the upper two posts on the HP NetServer are in the wide part of the upper two slots on the LCD cover, and the lower posts are free. When you feel that looseness, gently pull the LCD assembly away from the NetServer.
  • Page 26: Install The New Lcd Cover

    Chapter 2 Preparing the HP NetServer Install the New LCD Cover WARNING The LCD cover contains sheet metal with sharp edges. Handle it carefully to avoid injury. Do the following to assemble the new LCD cover: 1. Orient the LCD board to the rear half of the new LCD cover, as shown in Figure 2-12.
  • Page 27 Chapter 2 Preparing the HP NetServer 2. Thread the LCD power cord and ribbon cable through the rectangular hole in the rear half of the new LCD cover, as shown in Figure 2-12. CAUTION Be careful not to pinch the LCD cables between the LCD board and the rear LCD cover.
  • Page 28 Figure 2-14. Attaching the LCD Assembly (HP NetServer LXr 8500 Shown) CAUTION When you attach the LCD assembly to the HP NetServer, be careful not to pinch the LCD cables between the LCD assembly and the front of the HP NetServer.
  • Page 29: Reconnect The Lcd Cables

    Connector Top Flap of Ribbon Cable Connector Figure 2-15. Reconnecting the LCD Cables (HP NetServer LXr 8500 Shown) 2. Push the twisted pair connector onto the corresponding socket, as shown in Figure 2-15. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 30: Reinstall The Fan Cage, Fans, Fan Cover, And Top Cover

    2. Lower the fan cage into the chassis. Ensure that the tabs on the front of the processor tray enter the slots on the fan cage. Tipping the top of the fan cage slightly forward (away from the HP NetServer) aids this insertion. Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 31 3. Install all six fans. Orient them with their arrow labels pointing to the rear of the HP NetServer. The fans are keyed so that they must be oriented correctly before they can be inserted fully, with the top of the fan flush with the top of the fan cage.
  • Page 32 Chapter 2 Preparing the HP NetServer 5. Lower the top cover onto the top of the HP NetServer, about one half-inch (1 cm) to the rear of its normal position when closed. See Figure 2-18. Screws Top Cover Figure 2-18. Reinstalling the Top Cover (HP NetServer LXr 8500 Shown) 6.
  • Page 33: Attach The New Control Panel Bezel

    Attach the new control panel bezel, as shown in Figure 2-19. Push in the snap latches on the left and right ends of the control panel bezel, and gently push those latches into the two slots on the front of the HP NetServer indicated in the figure. Control Panel Bezel...
  • Page 34: Preparing The Rack

    (UPS). Determine the HP NetServer Location in the Rack Determine the location at which the HP NetServer is to be installed in the rack enclosure. Mark the bottom and top of this location on the rack columns. The HP NetServer LXr 8000 or 8500 measures 7 EIA units tall.
  • Page 35 3. Now mark two holes on each of the front columns to use for the cage nuts where the HP NetServer-attachment screws secure to the columns. 4. To mark the HP NetServer-attachment holes on the front columns (refer to Figure 3-1), count up from the bottom of the installation location (which is the top of the unit below), marking the 9th, and 17th holes.
  • Page 36: Install The Cage Nuts

    Chapter 3 Preparing the Rack Install the Cage Nuts Once you have marked the twelve holes, install a supplied cage nut in each marked hole on all columns, as shown in Figure 3-2. Cage Nut Column Figure 3-2. Installing Cage Nuts Adjust the Slides Prepare both slides for mounting, as shown in Figure 3-3: Rear Flange...
  • Page 37: Mount The Slides

    Chapter 3 Preparing the Rack 1. Loosen the two screws on the rear flange of the slide, but leave them in place. 2. Extend the rear flange by pushing it outward until the screws stop it. 3. Tighten the screws. NOTE The slides do not come apart;...
  • Page 38: Installing Into The Rack

    4 Installing into the Rack Overview of Installation into Rack If the HP NetServer is not yet mounted in the Compaq rack, do the following to mount it: Remove the power supply modules. Mount the HP NetServer on the slides.
  • Page 39 Chapter 4 Installing into the Rack Before you lift the HP NetServer, remove the power supply modules from the rear of the HP NetServer to reduce the weight and improve stability, as shown in Figure 4-1. Figure 4-1. Removing Power Supply Modules...
  • Page 40: Mount The Hp Netserver On The Slides

    (2 more on other side) Figure 4-2. Lifting the Server Onto the Slide Members 2. Using at least two people, lift the HP NetServer by using the lifting handles on each side. Move the HP NetServer in between the extended slide members and position it so that the handles are resting on the slide members, as shown in Figure 4-2 and Figure 4-3.
  • Page 41 Installing into the Rack Figure 4-3. Attaching the Slides to HP NetServer Chassis 3. Line up the mounting holes in the slide members with the holes in the HP NetServer chassis, insert the four screws on each side and tighten them, as shown in Figure 4-3.
  • Page 42 Figure 4-5. Location of Lockout Releases 6. Install two screws through the two holes on either side of the HP NetServer front, as shown in Figure 4-6, and into the cage nuts in the columns (previously installed in Chapter 3).
  • Page 43: Reinstall Power Supply Modules

    HP NetServer LXr 8000 or HP NetServer LXr 8500. 3. Orient the nameplate with the HP logo on the left, as shown in Figure 4-7. 4. Insert the tab on the left end of the nameplate into the corresponding slot in the front bezel indicated in Figure 4-7.
  • Page 44 Chapter 4 Installing into the Rack Slots Holes for Studs Nameplate HP Logo Tabs Compaq Rack-Optimized Front Bezel Figure 4-7. Attaching Nameplate to Compaq Rack-Optimized Front Bezel Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 45: Install The Compaq Rack Front Bezel

    Install the front bezel optimized for Compaq racks as follows: 1. Hold the bezel in front of the HP NetServer, as shown in Figure 4-8. Align the four studs on the back of the bezel with the four oval holes indicated in the figure.
  • Page 46: A Warranty And Support

    Hardware Accessories Limited Warranty An HP NetServer Hardware Accessory is an HP hardware product that is specifically designated for use with HP NetServers; is added on or integrated into an HP NetServer in order to provide higher performance, capacity, or increased capability;...
  • Page 47: Hp Repair And Telephone Support

    Appendix A Warranty and Support product by Customer from HP or Reseller. If HP or Reseller receives notice of such defects during the warranty period, HP or Reseller will either, at its option, repair or replace products that prove to be defective.
  • Page 48: Index

    Index Accessories, 7 EIA, 8 Adjusting rack slides, 31 Extending the HP NetServer, 11, 12 American Power Conversion Corporation (APC), 7 Fan cage, 17, 25 Anti-tip feature, 6 Fan cage light pipes, 17, 18, 24, 25 Fan cover, 15, 26...
  • Page 49 33 top cover, 15 Retainers, LCD cover, 22 Marking installation rack holes, 29 Mass storage devices, 7 Mounting HP NetServer on slides, 35 Securing HP NetServer, 37 Mounting rack slides, 32 Slide, 8 fastening HP NetServer, 36...