26

3.2 Cables

This section details how to instal and connect all the relevant cables to your E-Series
Display.

Siting and securing cables

When installing system cables, please note the following:
• All cables should be adequately secured, protected from physical damage and
exposure to heat. Avoid running cables through bilges or doorways, or close to
moving or hot objects.
• Connectors should be protected from damage. If it proves necessary to pull cables
through a bulkhead or deckhead using a cord, this should be attached several
inches behind the connector. Do not attach a tie immediately behind or
around the connector.
• Acute bends must be avoided.
• Where a cable passes through an exposed bulkhead or deckhead, a watertight
feed-through should be used.
• Secure cables in place using tie-wraps or lacing twine. Coil any extra cable and tie
it out of the way.
• Do not remove the SeaTalk High Speed blanking plug from the rear of the
display until such time as you are ready to connect the cable. Failure to adhere to
this, may result in the ingress of water and permanent damage to the display.

Connecting cables

CAUTION: Do not remove the SeaTalk High Speed blanking plug from
the rear of the display until such time as you are ready to connect the
cable. Failure to adhere to this may result in the ingress of water and
permanent damage to the display.
To ensure that your E-Series Display functions correctly, you will need to connect the
following cables:
• SeaTalk/Alarm Out cable (if SeaTalk system connected).
• NMEA cable (if third party equipment, NMEA multiplexer, fast heading sensor,
RS232 interface or course computer fitted).
• SeaTalk
• SeaTalk High Speed cable (if a DSM or second display is fitted).
• Video In cable (if a video player, on-board camera or DVD player fitted).
• Radar cable (not supplied).
• VGA Out cable (if an M1500 monitor or additional screen is fitted).
• Power cable.
2
2
cable (if Sea Talk
system connected).
E-Series Installation Manual