Summary of Contents for ICI CORONA CAMERA

  • Page 1 PLEASE READ THIS MANUAL BEFORE SWITCHING THE UNIT ON. IMPORTANT SAFETY INFORMATION INSIDE. ICI cameras fall under US Federal Law and Export Control. 2105 W. Cardinal Dr. Beaumont, TX 77705 For more information, contact us: (409) 861-0788 | sales@cameras.com | www.cameras.com...
  • Page 2 CORONA CAMERA USER MANUAL Revision History 07.2023-001 Document created...
  • Page 3: Table Of Contents

    CORONA CAMERA USER MANUAL Contents Disclaimers ���������������������������������������������������������� 6 Terms and Conditions ................. 6 U.S. Government Regulations ............. 6 Copyright ..................... 6 Quality Assurance ................6 Customer Help ..................6 User Notice����������������������������������������������������������� 7 Calibration ................... 7 Accuracy ..................... 7 Cybersecurity ..................7 Disposal of Electronic Waste ............
  • Page 4 CORONA CAMERA USER MANUAL 8-6-6 Playing Videos ..............27 8-6-7 Delete Videos ..............27 8-6-8 Transferring Media to an External Device ......28 8-6-8-1 MicroSD Card ............ 28 8-6-8-2 USB Mode ............28 8-6-9 Image Information ............... 29 Image Mode ..................30 8-7-1 Change Image mode ............30...
  • Page 5 CORONA CAMERA USER MANUAL 10-1 Cleaning the Lens ................45 10-2 Disinfecting the Camera Surface ..........45 10-3 Device Maintenance ................45 10-4 Storage .....................45 Troubleshooting �����������������������������������������������������46 11-1 The imager does not power on ............46 11-2 The imager shuts off unexpectedly ..........46 11-3 No UV image ..................46...
  • Page 6: Disclaimers

    CORONA CAMERA USER MANUAL Disclaimers Terms and Conditions Warranty Terms and Condition of Sale are made available online at: https://cameras.com/support/terms-and-conditions-of-sale/ 1-2 U.S. Government Regulations This product may be subject to U.S. Export Regulations. Please send any inquiries to support@cameras.com 1-3 Copyright ©...
  • Page 7: User Notice

    CORONA CAMERA USER MANUAL User Notice Calibration Annual calibration to the thermal camera is recommended. Contact customer service to schedule maintenance. Accuracy For very accurate results, we recommend that you wait a minimum of 5 minutes after you have started the camera before measuring a temperature.
  • Page 8: Intended Use

    CORONA CAMERA USER MANUAL Intended Use ICI’s Corona Camera is a non-destructive testing device which detects, pinpoints, and documents flash arc corona and arcing partial discharge. overhead transmission lines, high voltage substations, Environment of use: electrical utilities, research institute, electrical inspections, service providers, laboratories, among others.
  • Page 9: Training

    CORONA CAMERA USER MANUAL Training To read about training, visit: https://traininginstitute.com/...
  • Page 10: Safety Information

    CORONA CAMERA USER MANUAL Safety Information • Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. •...
  • Page 11 CORONA CAMERA USER MANUAL • Do not solder directly onto the battery. Damage to the battery may occur. • If there is a leak from the battery and the fluid gets into the eyes, do not rub the eyes. Flush well with water and immediately get medical care.
  • Page 12: Technical Specifications

    CORONA CAMERA USER MANUAL Technical Specifications Pixel Resolution 640 x 480 Operation Range -15 °C to 50 °C (5 °F to 122 °F) Storage Range -25 °C to 60 °C (-13 °F to 140 °F) Detector Array Custom Overlay Accuracy <...
  • Page 13 CORONA CAMERA USER MANUAL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Screen 5” LCD screen, 800 x 480 IP Rating IP54, CE IEC 010-1 Detector Array: custom Pixel Resolution: 640 x 480 Minimum Visible Light Sensitivity: 0.1 Lux Visible Camera Focus: automatic/manual Focus Range: 1.5 m ~ ∞...
  • Page 14: Structure

    CORONA CAMERA USER MANUAL Structure Appearance and Definitions of Housing Interface Sun cover LCD Screen Battery Bay Lens Cover Battery Power LED Charge Port Power Capture Focus In/Zoom In Focus Out/Zoom Out Gain + 13. Mode Record Gain - OK/Menu...
  • Page 15 CORONA CAMERA USER MANUAL Lens Cover 20. Lens 23. 24. Interface 22. AV Slot 23. Headphone/Microphone Slot 24. SD Card Slot 25. Micro USB...
  • Page 16: Package Includes

    CORONA CAMERA USER MANUAL Package Includes Corona Camera Battery x2 Battery Charger Power Adapter USB to Type-C Cable Micro USB to USB Memory Card ENSURE ALL SYSTEM EQUIPMENT AND COMPONENT ITEMS ARE PRESENT BEFORE BEGINNING INSTALLATION...
  • Page 17: Quick Start Instructions

    Camera to a tripod using the ¼”-20 mount located on the back of the device handle. The Corona Camera can be used as a handheld device. MAKE SURE TRIPODS DO NOT BLOCK THE DIRECT PATH OF PERSON(S) TO BE IMAGED TO ENSURE THE EQUIPMENT WILL NOT BE MOVED OR KNOCKED DOWN.
  • Page 18 CORONA CAMERA USER MANUAL TURN ON THE CAMERA BY PRESSING AND HOLDING THE POWER BUTTON FOR AT LEAST TWO SECONDS. Power on device. PRESS AND HOLD THE POWER BUTTON FOR MORE THAN 5 SECONDS TO SHUT DOWN THE CAMERA. THE IMAGER NEEDS SUFFICIENT WARM-UP TIME FOR THE MOST ACCURATE TEMPERATURE MEASUREMENTS AND BEST IMAGE QUALITY.
  • Page 19: Battery Installation

    CORONA CAMERA USER MANUAL Battery Installation MAKE SURE TO HOLD THE CAMERA FIRMLY IN BOTH HANDS WHEN REMOVING OR REPLACING BATTERY OR ATTACHING OR REMOVING THE BATTERY BAY COVER. Press and hold the battery bay Ensure metal contacts are aligned, button and lift upwards to open the then push battery into battery bay.
  • Page 20: Memory Card Installation

    CORONA CAMERA USER MANUAL Memory Card Installation Insert the Memory Card into the side of the Corona Camera device until a clicking sound is heard. DO NOT FORCE MEMORY CARD INTO THE SLOT. THE SIDE OF THE CARD WITH CONTACT PINS MUST BE INSERTED FIRST. IF THERE IS RESISTANCE FLIP THE CARD AROUND AND TRY AGAIN.
  • Page 21: Charging Instructions: Option 1

    LIGHT TURNS RED WHEN THE BATTERY IS PLACED AND CHARGING. WHEN THE BATTERY IS FULLY CHARGED THE LIGHT TURNS GREEN. ICI DOES NOT RECOMMEND CHARGING THE DEVICE WHILE IT IS ON A TRIPOD. LAY DEVICE FACE DOWN ON A FLAT AND STABLE DESK OR TABLE WHILE CHARGING.
  • Page 22: Charging Instructions: Option 2

    CORONA CAMERA USER MANUAL Charging Instructions: Option 2 REMOVE THE BATTERIES FROM THE DEVICE TO FOLLOW CHARGING METHOD. Insert batteries into battery charger. Plug the power adapter into the battery charger. Plug power adapter into a 110/120V electrical outlet. WHEN THE BATTERY IS NOT PLACED IN THE CHARGER THE INDICATOR LIGHT DOES NOT FLASH.
  • Page 23: Operation Instructions

    Plug the power adapter into a 110v/120V electrical outlet. 8-1-2 Charging via Power Adapter Plug the jack end of the power adapter into the Corona Camera. Plug the power adapter into a 110v/120V electrical outlet. ENSURE THE IMAGER IS NEAR ROOM TEMPERATURE BEFORE CHARGING THE DEVICE.
  • Page 24: User Interface

    CORONA CAMERA USER MANUAL User Interface The device interface appearance: Main Menu Image Settings Submenu Display Mode Date and Time Focus Mode UV Count Zoom Gain Value 13. Discharge Video Gallery Battery Life Image Gallery Memory Card Settings Access the Main Menu Users can access the Main Menu by pressing the OK button.
  • Page 25: Media Management

    CORONA CAMERA USER MANUAL Media Management 8-6-1 Capture an Image Images are captured and stored in the JPG format and videos in the AVI format. Find and aim the device at the target. Adjust the focus till the image is clear.
  • Page 26: Delete Images

    CORONA CAMERA USER MANUAL 8-6-4 Delete Images When an image is captured it will be stored to the memory card. Media can be deleted at any time as follows: Press OK to access the Main Menu. Use the Navigation buttons to select the Image Gallery.
  • Page 27: Playing Videos

    CORONA CAMERA USER MANUAL 8-6-6 Playing Videos When a video is captured it will be stored to the memory card. Video files are named and sorted by their recording time. Media can be viewed and played at any time as follows: Press OK to access the Main Menu.
  • Page 28: Transferring Media To An External Device

    CORONA CAMERA USER MANUAL 8-6-8 Transferring Media to an External Device 8-6-8-1 MicroSD Card The easiest way to move images from the device is to remove the memory card from the device and insert it into a proper computer port or adapter. Follow your company’s procedures for moving images and video files between devices.
  • Page 29: Image Information

    CORONA CAMERA USER MANUAL 8-6-8-2-2 Video Transmission Stream video to an external monitor as follows: Connect to the device to a computer using the USB cable. Power on the device. Press OK to access the Main Menu. Use the Navigation buttons to select the System Settings Press OK to open the submenu.
  • Page 30: Image Mode

    CORONA CAMERA USER MANUAL 8-7 Image Mode There are 3 image modes available: UV: ultraviolet image UV+: ultraviolet image overlay over the visible image Visible: digital image only 8-7-1 Change Image mode There are two ways to change the image.
  • Page 31: Uv Alarm Settings

    CORONA CAMERA USER MANUAL 8-8 UV Alarm Settings 8-8-1 Enable Alarms By default the imager alarm thresholds are disabled. Enable alarms as follows: Press OK to access the Main Menu. Use the Navigation buttons to select the System Settings Press OK to open the submenu.
  • Page 32: Alarm Threshold

    CORONA CAMERA USER MANUAL 8-8-2 Alarm Threshold The alarm threshold helps users refine UV detection. When an alarm thresholds are exceeded an audible alarm sounds. Adjust the alarm threshold as follows: Press OK to access the Main Menu. Use the Navigation buttons to select the System Settings Press OK to open the submenu.
  • Page 33: Image Settings

    A high gain can cause the discharge effect to become an oversized spot and it may block the visible image. Therefore, ICI recommends the use of high gain only during the initial detection; slowly reduce the gain to pinpoint the location of the discharge source.
  • Page 34: Photon Counting Interval

    CORONA CAMERA USER MANUAL 8-9-3 Photon Counting Interval Users can adjust the counting interval as follows: Press OK to access the Main Menu. Use the Navigation buttons to select Image Settings. Press OK to open the submenu. Use the Navigation buttons to select Photon Counting Interval.
  • Page 35: Uv Overlay Transparency

    CORONA CAMERA USER MANUAL 8-9-5 UV Overlay Transparency Users can set the transparency of UV images as follows: Press OK to access the Main Menu. Use the Navigation buttons to select Image Settings. Press OK to open the submenu. Use the Navigation buttons to select UV Overlay Transparency.
  • Page 36: Gps

    CORONA CAMERA USER MANUAL 8-10 GPS Enable the GPS to tag media as follows: Press OK to access the Main Menu. Use the Navigation buttons to select System Settings. Press OK to open the submenu. Use the Navigation buttons to select System Settings.
  • Page 37: System Settings

    CORONA CAMERA USER MANUAL 8-11 System Settings 8-11-1 Date and Time Settings 8-11-1-1 Change the Date The date format is YYYY/MM/DD. Change the date as follows: Press OK to access the Main Menu. Use the Navigation buttons to select System Settings.
  • Page 38: Language Settings

    CORONA CAMERA USER MANUAL 8-11-2 Language Settings The default language is English. Change the language as follows: Press OK to access the Main Menu. Use the Navigation buttons to select System Settings. Press OK to open the submenu. Use the Navigation buttons to select System Settings.
  • Page 39: Power Management Settings

    CORONA CAMERA USER MANUAL 8-11-4 Power management Settings 8-11-4-1 Automatic Shutdown To save power users can change the auto shut off settings. Change power management settings as follows: Press OK to access the Main Menu. Use the Navigation buttons to select System Settings.
  • Page 40: File Name Display

    CORONA CAMERA USER MANUAL 8-11-5 File Name Display Users can change the amount of time the file saving notification displays on screen. Adjust the amount of time as follows: Press OK to access the Main Menu. Use the Navigation buttons to select System Settings.
  • Page 41: Format The Sd Card

    CORONA CAMERA USER MANUAL 8-11-7 Format the SD Card Users can format the memory card as follows: Press OK to access the Main Menu. Use the Navigation buttons to select System Settings. Press OK to open the submenu. Use the Navigation buttons to select Format.
  • Page 42: Memory Card Information

    CORONA CAMERA USER MANUAL 8-11-9 Memory Card Information Users can view memory card information as follows: Press OK to access the Main Menu. Use the Navigation buttons to select System Settings. Press OK to open the submenu. Use the Navigation buttons to select SD Card Info.
  • Page 43: Fundamentals Of Corona Discharge

    Understanding the mechanisms behind corona discharges and their effects is essential for the maintenance and longevity of power systems. The ability to detect and monitor UV radiation emissions, as achieved with ICI’s Corona Camera, offers valuable insights into these processes, even during daylight hours.
  • Page 44: Benefits Of Corona Inspections

    CORONA CAMERA USER MANUAL Benefits of Corona Inspections Infrared cameras may miss certain electrical issues due to solar loading when objects or surfaces being examined absorb heat, resulting in an increase in temperature and an obstruction or distortion of thermal readings. For this reason, infrared cameras face limitations during the day and inspections are best performed in the evening.
  • Page 45: Cleaning And Maintenance

    CORONA CAMERA USER MANUAL Cleaning and Maintenance 10-1 Cleaning the Lens Do not use corrosive chemicals on the optical glass components. Dust, grease, and fingerprints may produce harmful substances and lead to a decline in performance, or cause scratches. If dirt is found, please use the following...
  • Page 46: Troubleshooting

    CORONA CAMERA USER MANUAL Troubleshooting If the user encounters any problems while using the imager, refer to the following options. If the problem persists, disconnect the power and contact the customer support department. 11-1 The imager does not power on •...
  • Page 47: Alarm Not Sounding

    CORONA CAMERA USER MANUAL 11-8 Alarm not sounding • Turn off the device; then, turn it back on • Enable alarms • Adjust alarm threshold...
  • Page 48: About Ici

    CORONA CAMERA USER MANUAL About ICI ICI manufactures complete systems and software. We can provide complete engineering, software, and OEM solutions. Our Fortune 500 clients rely on us for equipment and thermography training (which we offer through the Infrared Training Institute).

Table of Contents