Advertisement

Quick Links

Edit Text
Out
Revision: 11.2022-001
Industry
Ind
FMX 400/FMX 700 SERIES
USER MANUAL
PLEASE READ THIS MANUAL BEFORE SWITCHING THE UNIT ON.
IMPORTANT SAFETY INFORMATION INSIDE.
ICI cameras fall under US Federal Law and Export Control.
2105 W. Cardinal Dr. Beaumont, TX 77705
For more information, contact us: (409) 861-0788 | sales@infraredcameras.com | www.infraredcameras.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FMX 400 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ICI FMX 400 Series

  • Page 1 PLEASE READ THIS MANUAL BEFORE SWITCHING THE UNIT ON. IMPORTANT SAFETY INFORMATION INSIDE. ICI cameras fall under US Federal Law and Export Control. 2105 W. Cardinal Dr. Beaumont, TX 77705 For more information, contact us: (409) 861-0788 | sales@infraredcameras.com | www.infraredcameras.com...
  • Page 2 FMX 400/FMX 700 SERIES USER MANUAL Revision History 11.2022-001 Document created...
  • Page 3: Table Of Contents

    FMX 400/FMX 700 SERIES USER MANUAL Contents Disclaimers ���������������������������������������������������������� 5 Terms and Conditions ................. 5 U.S. Government Regulations ............. 5 Copyright ..................... 5 Quality Assurance ................5 Customer Help ..................5 User Notice����������������������������������������������������������� 6 Calibration ................... 6 Accuracy ..................... 6 Cybersecurity ..................
  • Page 4 Thermal imager shuts off unexpectedly .........25 11-3 No thermal image ................25 11-4 Camera out of focus ................25 11-5 Unclear or dark visible images ............26 11-6 Temperature readings are incorrect ..........26 11-7 Network recognized but not connected .........26 About ICI ������������������������������������������������������������27...
  • Page 5: Disclaimers

    FMX 400/FMX 700 SERIES USER MANUAL Disclaimers Terms and Conditions Warranty Terms and Condition of Sale are made available online at: https://infraredcameras.com/support/terms-and-conditions-of-sale/ 1-2 U.S. Government Regulations This product may be subject to U.S. Export Regulations. Please send any inquiries to support@infraredcameras.com 1-3 Copyright ©...
  • Page 6: User Notice

    FMX 400/FMX 700 SERIES USER MANUAL User Notice Calibration Annual calibration to the thermal camera is recommended. Contact customer service to schedule maintenance. Accuracy For very accurate results, we recommend that you wait a minimum of 5 minutes after you have started the camera before measuring a temperature. Cybersecurity After the products are connected to the Internet, they may face risks including but not limited to network attacks, hacker attacks, virus infections, etc.
  • Page 7: Intended Use

    FMX 400/FMX 700 SERIES USER MANUAL Intended Use The FMX 400/FMX 700 Series cameras are used for surface temperature assessment of energy emitted from the first 1/1000 of an inch of a subject. industrial and petrochemical buildings, electrical plants, Environment of use: security rooms, science labs, animal reserves as well as environmental conservatories, among others.
  • Page 8: Training

    FMX 400/FMX 700 SERIES USER MANUAL Training To read about infrared training, visit: https://infraredtraininginstitute.com/...
  • Page 9: Safety Information

    FMX 400/FMX 700 SERIES USER MANUAL Safety Information • This device must be installed by qualified service personnel or system installation personnel. • Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 10 FMX 400/FMX 700 SERIES USER MANUAL • Do not put the product into a fire. • It is recommended to calibrate the device(s) annually. • If the device operates abnormally, please contact the supplier and do not dismantle the device on your own. THE ENCAPSULATION RATING IS ONLY APPLICABLE WHEN ALL THE OPENINGS ON THE CAMERA ARE SEALED WITH THEIR CORRECT COVERS, HATCHES, OR CAPS.
  • Page 11: Technical Specifications

    FMX 400/FMX 700 SERIES USER MANUAL Technical Specifications FMX 400 P FMX 700 P Pixel Resolution 384 x 288 640 x 512 Accuracy ± 2 °C (± 3.6 °F) or ± 2% -20 °C to 120 °C -20°C to 550°C Temperature Range (-4 °F to 248 °F) (-4°F to 1022°F)
  • Page 12 FMX 400/FMX 700 SERIES USER MANUAL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE FMX 400 P FMX 700 P Video Emissivity Correction 0.01 to 1.0 IP Rating IP54 Internal non-uniformity correction (NUC) 1/4”-20 tripod supp SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE...
  • Page 13: Structure

    FMX 400/FMX 700 SERIES USER MANUAL Structure Appearance and Definitions of Housing Interface Germanium Lens LED Indicator Light Power Interface Data Interface RJ-45 Internet access Reset Button...
  • Page 14: Package Includes

    FMX 400/FMX 700 SERIES USER MANUAL Package Includes FMX Series device Ethernet Cable Power Adapter Software USB Drive Coaxial Cable ENSURE ALL SYSTEM EQUIPMENT AND COMPONENT ITEMS ARE PRESENT BEFORE BEGINNING INSTALLATION...
  • Page 15: Quick Start Instructions

    FMX 400/FMX 700 SERIES USER MANUAL Quick Start Instructions Setup Mount the FMX Series device to a tripod using the ¼-20 mount. MAKE SURE TRIPODS DO NOT BLOCK THE DIRECT PATH OF PERSON(S) TO BE IMAGED TO ENSURE THE EQUIPMENT WILL NOT BE MOVED OR KNOCKED DOWN.
  • Page 16 FMX 400/FMX 700 SERIES USER MANUAL ENSURE THE CAMERA LENS AND TEMPERATURE REFERENCE SOURCE ARE FACING EACH OTHER ON PARALLEL PLANES. MAKE SURE CAMERA TARGET AREA IS FACING A NON-REFLECTIVE BACKGROUND. Plug Ethernet cable into the Ethernet Plug the other end of the Ethernet cable port of the FMX Series device.
  • Page 17: Software Installation

    FMX 400/FMX 700 SERIES USER MANUAL Plug power adapter into a 110/120V Power on Devices. electrical outlet. ALLOW AT LEAST 10 MINUTES FOR THE DEVICE TO ACCLIMATE. THIS WILL PROVIDE THE MOST ACCURATE TEMPERATURE MEASUREMENTS. Software Installation Install IR Flash software using the Once installed, launch IR Flash software USB drive.
  • Page 18: Operation Instructions

    FMX 400/FMX 700 SERIES USER MANUAL Operation Instructions IP Address Configuration The FMX 400 and 700 comes configured with static IP address for the infrared camera. The infrared camera lies at 192.168.10.117. Connecting the computer requires setting the IPv4 settings of the Ethernet port to a static IP address in the same “Class C.”...
  • Page 19: Ir Flash Pro

    FMX 400/FMX 700 SERIES USER MANUAL IR Flash Pro Software arrives installed on computers and tablets purchased from ICI as complete systems and it will launch automatically on startup. A copy of the software is provided on the Software USB Drive.
  • Page 20: Cleaning And Maintenance

    FMX 400/FMX 700 SERIES USER MANUAL Cleaning and Maintenance Cleaning the Germanium Lens Do not use corrosive chemicals on the optical glass components. The germanium window surface is coated with anti-reflection coating. Dust, grease, and fingerprints will produce harmful substances and lead to a decline in performance, or cause scratches.
  • Page 21: Radiometry

    FMX 400/FMX 700 SERIES USER MANUAL Radiometry 10-1 Introduction to Radiometry The basic reason for employing image processing programs when analyzing IR images is to have a fast and comprehensive means to determine the information content of an image in numerical terms. Radiometry is considered the base from which to conduct this analysis.
  • Page 22: Detail Parameters

    FMX 400/FMX 700 SERIES USER MANUAL 10-2-1 Detail Parameters Name, Date, and Time information is automatically recorded and stored when and image is captured. Images have a default name of “XXYZ_IR” where “X” is a series of numbers. Users can enter notes in the Comments section. Location/ GPS is captured if enabled.
  • Page 23: Ambient Temperature

    FMX 400/FMX 700 SERIES USER MANUAL 10-2-3 Ambient Temperature The Ambient Temperature, which is often referred to as the background, is the temperature of the air surrounding the target object. This number can affect surfaces whose energy will hit the face of the target object and reflect from it into the camera’s field of view.
  • Page 24: Histograms & Graphs

    FMX 400/FMX 700 SERIES USER MANUAL 10-3 Histograms & Graphs The bottom right corner of the screen plots image information in the form of a histogram or a 3D rendering. It also allows users to visualize the temperature data over time for any/all ROIs placed on the image; the last image below shows a plot for three Regions of Interest.
  • Page 25: Troubleshooting

    FMX 400/FMX 700 SERIES USER MANUAL Troubleshooting If the user encounters any problems while using the imager, refer to the following options. If the problem persists, disconnect the power and contact the customer support department. 11-1 Camera(s) not showing, camera(s) lagging, or software crashing •...
  • Page 26: Unclear Or Dark Visible Images

    FMX 400/FMX 700 SERIES USER MANUAL 11-5 Unclear or dark visible images • Turn on lights in imaging area • If lens is foggy, use professional equipment to clean the lens 11-6 Temperature readings are incorrect • Turn off the device; then, turn it back on •...
  • Page 27: About Ici

    FMX 400/FMX 700 SERIES USER MANUAL About ICI ICI manufactures complete systems and software. We can provide complete engineering, software, and OEM solutions. Our Fortune 500 clients rely on us for infrared equipment and thermography training (which we offer through the Infrared Training Institute).

This manual is also suitable for:

Fmx 700 seriesFmx 400 pFmx 700 p

Table of Contents