Download Print this page

Replacement Parts / Accessories; Warranty Statement; Installation Of Remote Accessory Lamp With Uvcap; Remote Accessory Lamp Installation (With Main Unit) - Carrier UVCAPXXC2015 Installation & Operation Manual

Carbon air purifier with uv

Advertisement

UVCAPXX2015: Installation & Operation Manual

Replacement Parts / Accessories

CAUTION
!
PARTS AND ACCESSORIES USE
To ensure product reliability and warranty, use only Carrier specified
replacement parts and accessories.
Table 2 – Replacement Parts / Accessories
Part Number
Carbon Air Purifier Parts
P201-3401
UVCAPXXC2015C
UVCAPXXC2015L
Accessory Lamp Parts
UVCAPXXC2015A
UVCAPXXC2015AL
Accessory Lamp Add-On Unit Replacement
HT01BD118
*. Requires 75VA Transformer

Warranty Statement

The Carbon Air Purifier with UV is covered by a limited warranty.
Please see the included warranty card for clarification.
Installation of Remote Accessory Lamp with
UVCAP
IMPORTANT: When installing the UVCAP with remote accessory
lamp do not use 40VA transformer provided with the UVCAP unit. You
must use the 75VA transformer referenced in
NOTE: This accessory lamp complies with part 18 of the FCC Rules.
WARNING
!
PERSONAL INJURY OR UNIT DAMAGE HAZARD
Failure to follow this caution could result in damage to unit or personal
injury.
Perform visual inspection of potential mounting location by removing
unit/cabinet door prior to cutting or drilling. Be careful not to cut, drill
or drive screws into coil, refrigerant lines or other objects inside the
HVAC unit.
Remote Accessory Lamp Installation (with Main
Unit)
1. Light stick connection will receive power from WAGO connection
located on the UVCAP unit
2. Push two wires from light stick power supply into WAGO
connection.
3. Insure tight connection in WAGO terminal and test operation.
IMPORTANT: When installing UV light stick in combination with
UVCAP unit do not use the 40VA transformer included with the
UVCAP unit. A 75VA transformer must be field supplied and installed
(Table
2).
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Description
40VA Transformer
Carbon Core Replacement
Lamp Replacement
*
Accessory Lamp Add-On Unit
75VA Transformer
Table
2.
(Fig.
7).
Fig. 7 – WAGO Terminals

W-coil / Above A-coil (Remote Lamp)

1.
(Fig.
8) Disconnect power to the air handler and open access
panels.
2. Standard Bracket Installation – Install the lamp bracket at the
desired location with two self-drilling screws (included).
3. Secure the lamp to the lamp bracket with the provided knurled nuts.
4. Connect remote mount lamp power cord.
Attach lamp to lamp bracket and install in desired location.
Fig. 8 – W-coil / Above A-coil Install (Remote Lamp)

A-coil Delta Plate (Remote Lamp)

1.
(Fig.
9) Drill a 7/8" hole into the delta plate and place gasket
(included) around hole.
2. Insert lamp directly into hole and secure the lamp to the delta plate
with two self-drilling screws (screws and rubber washers included).
3. Connect remote mount lamp power cord.
NOTE: A-coil delta plate installation does not use lamp bracket.
Gasket
Insert lamp into delta plate hole and secure with
screws and washers. Connect remote lamp power cord.
Fig. 9 – A-coil Delta Plate Install (Remote Lamp)
5
A221366
A221221
Rubber Washers
A221222

Advertisement