Error Codes
The induction cooktop is equipped with a self-diagnostic function. With this test the
technician can check the function of several components without disassembling or
dismounting the hob from the working surface.
Error code
E1
E2
E3
E4
E5
E6
F3/F6
F4/F7
F5/F8
F9/FA
FC /FD
26
Problem
Auto-Recovery
Supply voltage is above
the rated voltage.
Supply voltage is below
the rated voltage
High temperature of
ceramic plate sensor. (1#)
High temperature of
ceramic plate sensor. (2#)
High temperature of
IGBT. (1#)
High temperature of
IGBT. (2#)
No Auto-Recovery
Ceramic plate
temperature sensor
failure- -short circuit. (F3
for 1#, F6 for2#)
Ceramic plate
temperature sensor
failure--open circuit. (F4
for 1#, F7 for2#)
Ceramic plate
temperature sensor failure
invalid. (F5 for 1#, F8
for2#)
Temperature sensor of
the IGBT failure. (Short
circuit/open circuit for 1#)
Temperature sensor of
the IGBT failure. (Short
circuit/open circuit for 2#)
Solution
Please inspect whether
power supply is normal.
Power on after the power
supply is normal.
High temperature of
ceramic plate sensor.
Touch power button to
restart unit.
Wait for the temperature
of IGBT return to normal.
Touch power button to
restart unit.
Check whether the fan
runs smoothly; if not,
replace the fan.
Check the connection or
replace the ceramic plate
temperature sensor.
Replace the power board.

Advertisement