National Instruments NI DCM-2316 Getting Started Manual

National Instruments NI DCM-2316 Getting Started Manual

Embedded direct injector control and measurement (dcm) device with real-time processor and reconfigurable fpga

Advertisement

Quick Links

GETTING STARTED GUIDE
NI DCM-2316
Embedded Direct Injector Control and Measurement (DCM) Device
with Real-Time Processor and Reconfigurable FPGA
Hazardous Voltage
take the following precautions. A hazardous voltage is a voltage greater than 42.4
Vpk voltage or 60 VDC to earth ground.
Caution
personnel adhering to local electrical standards.
Caution
the same cable unless the cables are properly insulated for min. 250V.
Caution
insulated from human contact.
Caution
Ethernet Port, all I/O terminals are hazardous voltage LIVE (> 42.4 Vpk/60 VDC) or
could be at hazardous potential. You must ensure that devices and circuits connected
to the module are properly insulated from human contact. External protection must
be provided to protect any other devices connected to the BATT, DRVP, and MPRD
supplies.
This device sources hazardous voltages up to 250V. You must
Ensure that hazardous voltage wiring is performed only by qualified
Do not mix hazardous voltage circuits and human-accessible circuits in
Ensure that devices and circuits connected to the module are properly
Except for the isolated RS232, CAN, IGND, IO Lock terminals, and the

Advertisement

Table of Contents
loading

Summary of Contents for National Instruments NI DCM-2316

  • Page 1 GETTING STARTED GUIDE NI DCM-2316 Embedded Direct Injector Control and Measurement (DCM) Device with Real-Time Processor and Reconfigurable FPGA This device sources hazardous voltages up to 250V. You must Hazardous Voltage take the following precautions. A hazardous voltage is a voltage greater than 42.4 Vpk voltage or 60 VDC to earth ground.
  • Page 2: About This Manual

    About This Manual This document explains how to begin using the National Instruments DCM family of devices. The scope is limited to focus on initial DCM startup and basic operation using the DCM Starter Harness and DSI software.
  • Page 3: Software Installation

    NI CompactRIO Device Drivers 16.0 or later • NI Powertrain Controls Device Drivers 2.160.0.0 or later Minimum power supply requirements assume basic operation; actual power supply requirements will vary depending on hardware and software configuration. NI DCM-2316 Getting Started Guide | © National Instruments | 3...
  • Page 4: Hardware Installation

    Remove the screw from the chassis ground lug on the DCM. Insert wire or braided grounding strap into the side of the chassis ground lug Tighten the grounding screw to 1.4 N · m (12 lb · in.) of torque. 4 | ni.com | NI DCM-2316 Getting Started Guide...
  • Page 5 Connect the harness to the PDU (blue connector). Connect the harness to the emergency stop. Connect Solenoid A1 injector (real or dummy). Connect Piezo A2 injector (real or dummy). NI DCM-2316 Getting Started Guide | © National Instruments | 5...
  • Page 6 Remove 7.5 A fuses from slots F12 and F13 and set aside. Fill slot F14 (empty by default) with one of the 7.5 A fuses removed in the previous step. Save the remaining fuse as a replacement. 6 | ni.com | NI DCM-2316 Getting Started Guide...
  • Page 7 (24 VDC, 20 A, 100-240 VAC/110-150 VDC Input) Tripp Lite PR 60 PR 60 (13.8 VDC, 60 A, 120 VAC Input) TDK Lambda Genesys 1500W GEN 30-50 (0-30 VDC Variable, 0-50 A Variable, 85-265 VAC input) NI DCM-2316 Getting Started Guide | © National Instruments | 7...
  • Page 8 MAX uses UDP 44525. Refer to the documentation of your firewall software Note for information about configuring the firewall to allow communication through UDP 44525. • Launch MAX on the host computer. 8 | ni.com | NI DCM-2316 Getting Started Guide...
  • Page 9 11. Click OK to confirm you are changing the password. NI cannot recover lost system passwords. If you forget the password, you Caution must contact NI and reformat the controller. NI DCM-2316 Getting Started Guide | © National Instruments | 9...
  • Page 10 To install NI VeriStand or NI SCM on the target, continue with the following steps. In MAX, right-click Software as before. Select Add/Remove Software to launch the LabVIEW Real-Time Software Wizard. You must log in if you set a system password. 10 | ni.com | NI DCM-2316 Getting Started Guide...
  • Page 11 +AI11 (pin 63) to Batt+ Cycle Power • Console Out Enabled • Network Settings Reset Safe Mode with IP Reset • RT Startup App Disabled Cycle Power • FPGA Startup App Disabled NI DCM-2316 Getting Started Guide | © National Instruments | 11...
  • Page 12 Flashing unrecoverable error. Contact National or Solid Instruments. USER 1 — — Application dependent USER 2 ACT/LINK — No Ethernet link Green Solid Ethernet link established Green Blink Ethernet activity occurring 12 | ni.com | NI DCM-2316 Getting Started Guide...
  • Page 13: Related Documentation

    • NI DCM-2301 Specifications—Lists the specifications of the NI DCM-2301 device. This document is available at ni.com/manuals • NI DCM-2316 Specifications—Lists the specifications of the NI DCM-2316 device. This document is available at ni.com/manuals Software Documentation • NI Powertrain Controls Device Drivers User’s Manual –...
  • Page 14: Worldwide Support And Services

    For telephone support outside the United States, visit the Worldwide Offices section of to access the branch office websites, which provide up-to-date contact ni.com/niglobal information, support phone numbers, email addresses, and current events. 14 | ni.com | NI DCM-2316 Getting Started Guide...
  • Page 15 For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patents Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product.

Table of Contents