3

Technical Specifications

3.1

Technical Data

NOTE: All data in this section are nominal
values and subject to normal production
tolerances.
Flow Temperature (adjustable)
30° C to 80° C (± 5° C)
7668918-01 (10/16)
Outercase Dimensions
Overall Height
-
Inc Flue Elbow
Casing Height
-
Casing Width
-
Casing Depth
-
Clearances
Both Sides
5mm Min
Above Casing
190mm Min
(Top Flue)
Above Casing
35mm Min
(Rear Flue)
Below Casing
35mm Min
(in Cupboard)
Below Casing
120mm Min
Front (For Servicing)
500mm Min
Front (In Operation)
5mm Min
Ventilation of Compartment
Where the boiler is installed in a cupboard
or compartment, no air vents are required
for cooling purposes providing that the
minimum dimensions above are maintained.
Electrical Supply
(Appliance must be connected to an
790mm
625mm
370mm
Power Consumption
280mm
13 model
16 model
19 model
25 model
30 model
External Fuse Rating
Technical Specifications
230V~ 50Hz
earthed supply)
17W
20W
23W
33W
44W
3A
Assure Heat