Download Print this page

Electrical; Preparing The Environment; Hardware Installation - National Instruments PXIe-8240 Getting Started Manual

Hide thumbs Also See for PXIe-8240:

Advertisement

1.
Touch the antistatic package to a metal part of the chassis before removing the device
from the package.
Caution
2.
Remove the device from the package and inspect the device for loose components or any
other sign of damage.
3.
Notify National Instruments if the device appears damaged in any way. Do not install a
damaged device into your chassis.

Electrical

Power Rail
+3.3 VDC
+12 VDC
Total Power

Preparing the Environment

Ensure the environment you are using the PXIe-8240 in meets the following specifications.
Ambient temperature range
Relative humidity range
Maximum altitude
Pollution Degree
Indoor use only.
Note
Refer to the PXIe-8240 User Manual for full PXIe-8240 specifications.

Hardware Installation

The following are general instructions for installing the PXIe-8240.
Complete the following steps to install the PXIe-8240 in your PXI Express chassis.
1.
Power off your PXI Express chassis, but leave it plugged in while installing the
PXIe-8240. The power cord grounds the chassis and protects it from electrical damage
while you install the module.
Caution
leave the chassis off until you finish installing the PXIe-8240.
2.
Remove or open any doors or covers blocking access to the slot in which you intend to
install the PXIe-8240.
2 | ni.com | PXIe-8240 Getting Started Guide
Never touch the exposed pins of connectors.
Typical Value
15.31 W
To protect both yourself and the chassis from electrical hazards,
0.64 A
1.1 A
0 °C to 55 °C (Tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2.)
10% to 90%, noncondensing (Tested in
accordance with IEC-60068-2-56.)
2,000 m (800 mbar)
2
Max Value
0.96 A
1.65 A
22.97 W

Advertisement

loading