Fan Setup - Vents Style Series User Manual

Axial fan
Table of Contents

Advertisement

FAN SETUP

: to adjust the humidity set point turn the control knob
humidity sensor set point, adjustable from 60% up to 90%.
: turning of the interval timer on and its adjustment is performed with the potentiometer
off, set the potentiometer
operation for 6 hours, rotation of the potentiometer for 2/3 clockwise sets the interval timer operation for 12 hours, rotation
of the potentiometer clockwise in the rightmost position sets the interval timer operation for 24 hours.
: to adjust the fan turn-off delay time, turn the control knob
decrease the turn-off delay time respectively, adjustable from 2 up to 30 minutes.
Attention! If the switch opens within 60 seconds after its closing, the fan operating status does not change.
Attention! After closing of the switch S the front
panel opens within 1 minute. After opening of the
switch S (for basic model) or after countdown of
the turn-off delay time (for T and TH models) the
front panel closes within 1 minute.
The fan delivery set includes a specially designed
plastic screwdriver for fan settings adjustments.
Use it for setting the on-delay time, off-delay time and
humidity setpoint.
T
into the leftmost position. Rotation of the potentiometer for 1/3 clockwise sets the interval timer
i
DO NOT USE A METAL SCREWDRIVER, KNIFE, ETC. FOR ADJUSTMENT
OPERATIONS NOT TO DAMAGE THE CIRCUIT BOARD
H
clockwise to increase and counter-clockwise to decrease the
T
clockwise to increase and counter-clockwise to
off
9
EN
T
. To turn the interval timer
i
H
for TH
60%
90%
T
i
for
O
24 hour
T
o
for /TH
2 min
30 min