Service and maintenance
10.1 Error and diagnostics messages
10.1.3

Error output of the read results

Table 10- 2
Error output of the read results
Message
Error message
number
1
Read error
(<Reason>)
2
Filter error
(<Reason>)
3
Match error
(<Read result> !
<Match string>)
4
Format error
(<Reason>)
Note
Changing error texts
Note that the error messages in the WBM can be changed under "Application > Program >
Event > Error messages".
180
Description
The processing was not successful in
processing mode.
The selected result string filtering
was not possible with the read code.
The configured comparison op-
tion was not found in the code to
be compared.
The string defined for training
does not match the current string
of the code or the plain text.
The configured format text does not
match the definition.
Corrective measures
For possible causes, refer to "Read and
verification error messages" for the error
messages.
1. Check whether the code just read is
correct.
2. Check and, if necessary, correct the
selected result settings in the decoder
step in the "Result" tab.
Check the selected result settings.
Check the selected settings.
You can find additional information in
"Overall result" in the online help.
The undefined formatting command is
issued as <reason>.