Process interfacing via an automation system (PLC, PC)
9.9 Example programs
Area: Connection
Apply the entries for the IP address and port that you have configured under "Settings >
Communication > Interfaces > Archiving/MMI" in the WBM.
● Select the IP address from the "Local IP Address" drop-down list.
● Enter the port in the "Port" text box.
● Enter the desired time in the "Timeout [sec]" text box.
If the example program has not received a response from the optical reader for the
specified amount of time, the example program terminates the connection to the optical
reader.
Enter the value "0" in the input box to disable Timeout monitoring.
Area: Output
"Save Bitmaps to ..." and "Save CSV files to ...":
● Specify the storage path under which the diagnostic images and CSV files are saved.
"Bitmap Filename Template" and "CSV Filename Template":
In these input boxes, you can define specifications for naming the generated files.
You can use the following placeholders:
● %Date%
Is replaced with the current date or the date stamp of the image acquisition in the "Year-
Month-Day" format.
● %Time%
Is replaced with the current time or the time stamp of the image acquisition in the "Hours-
Minutes-Seconds-Milliseconds" format.
● %DeviceType%
Replaced by the device type of the connected optical reader, e.g. "MV540-H".
● %Uid%
Replaced by a random unique ID of the image (24 digits).
Use a backslash ("\") to define subfolders. The subfolders are created below the output
folders.
"max. Entries per CSV"
● In the input box, enter the maximum number of lines a CSV file is to contain.
A new CSV file is created as soon as the maximum number of lines is exceeded.
172
Operating Instructions, 05/2019, C79000-G8976-C494-02
SIMATIC MV500