Westinghouse WWT9084C7SA User Manual page 32

Table of Contents

Advertisement

32
www.westinghouse.com.au / www.westinghouse.co.nz
Display
Description
Code
Motor
E50
E50
problems
UI -MB communication
E91
E91
error
Power supply frequency
E E H H 0 0
out of limits
Power supply voltage too
high
Power supply voltage too
low
Drive train triac failure
E E C C 0 0
(actuator)
Foam warning
E E F F 0 0
Load too unbalanced
system
Possible fault
- Motor defective
- Motor Wiring or Motor Control board
defective
- Overload condition
- Wiring defective, or UI,
MB board defective
- Wrong or disturbed Power Supply line.
- Main board defective
- Wrong or disturbed Power Supply line.
- Main board defective
- Wrong or disturbed Power Supply line.
- Main board defective
- TY5 triac load device defective
(drive train device)
- Wiring or main board defective
- Excessive detergent dosing
- Drain filter dirty or clogged
- Drain pipe kinked or clogged
- Load unbalanced