Quantum Scalar i2000 Release Note page 9

I6.3.1 575a.gs00101
Hide thumbs Also See for Scalar i2000:
Table of Contents

Advertisement

Change
Service
Request
Request
Number
Number
70621
70638
70591
69075
69061
69021
68949
66625
66379
65583
Description
The 7404 GUI reboot operation is slow
(approximately 20 seconds).
Installing EKM with IBM Java disables
functioning Sun Java plug-in and i2000 RMI
interface does not function after EKM install.
Q-EKM enabled systems with more than 36
LTO-4 drives may fail with key/ASC/ASCQ:
4/ee/e. This type of failure only occurs during
extremely high amounts of key requests (or
move medium commands).
Drives failed to autolevel to specified firmware
image during library bundle upgrade.
Error connecting to server after software
upgrade
Devices stopped responding to host (all cmds
timed out) following port reset.
Modifying a one-partition library to remove
magazines from the partition does not remove
all magazines selected upon completion. If the
user attempts to create a partition using the
available magazine, two partitions checker
board the library.
Long erase fails with BUE 11d w/HP LTO3;
semaphore timeout after 6 hours.
7404 HPF requires reboot of SUSE 9 UD4
server.
7404 HPF: the active port setting is not
persistent, and a reboot can set it back to a
failing port.
Known Issues
Document 6-00424-40 Rev A
Workaround
No applicable workaround is available.
Let the reboot process complete.
Since the Mozilla Firefox Java plug-in is
not impacted by the EKM installation, it
is recommended to use Firefox if there
are issues.
Restart back-up through host
application.
Do not upgrade drive brick firmware
using the Tools > Upgrade Software
menu option, but perform the upgrade
after successfully updating the software
library, using Tools > Update Drive
Firmware menu option.
When managing multiple libraries, do
not use the same host for different GUIs
at the same time.
Before pulling cables from the FC
blades, verify that no I/O data is being
written or read from the drives.
Delete all partitions, and then use the
Expert mode to create both partitions.
Device drivers from several different
vendors, such IBM LTO and Adaptec
SCSI HBA, have had to made changes
to address LTO erase timeout issues. At
minimum user needs to check and
update to latest version of the device
drivers for their system. Then if
necessary, either run tape long erase
operation one at a time or install IBM
LTO 6.0.8.2 driver.
Reboot SUSE 9 host.
This functions as designed.