Ports & Devices; Maintenance - Axis 0942-001 User Manual

Ptz network camera
Table of Contents

Advertisement

AXIS Q6055-C PTZ Network Camera
About system options
Network Share
Network share allows you to add network storage such as a NAS (network-attached storage). The NAS shall be dedicated for
recordings and data from the Axis products connected to the network. For information about reference NAS devices, go to
www.axis.com/products/axis-companion/support-and-documentation
Note
For NAS recommendations see www.axis.com
To add a network share:
1. Go to System Options > Storage.
2. Click Network Share.
3. Enter the IP address, DNS or Bonjour name to the host server in the Host field.
4. Enter the name of the share in the Share field. Sub folders cannot be used.
5. If required, select The share requires login and enter the user name and password.
6. Click Connect.
To clear all recordings and data from the Axis product's folder on the designated share, click Clear under Storage Tools.
To avoid filling the share, it is recommended to remove recordings continuously. Under Recording Settings, select Remove recordings
older than and select the number of days or weeks.
To stop writing to the share and protect recordings from being removed, select Lock under Recording Settings.
Ports & Devices
I/O Ports
The media converter switch provides two configurable input and output ports for connection of external devices. One port is
dedicated for the I/O signals between the media converter switch, the supplied multicable and the camera. For more information
about the multicable, see page 66.
To configure the I/O ports, go to System Options > Ports & Devices > I/O Ports. Each port can function as input or output:
Input as Open circuit – The input becomes active when the circuit is grounded by, for example, a REX device. It remains
inactive as long as its normal state equals its current status.
Input as Grounded circuit – The input becomes active when the circuit is opened by for example a monitor.
Output as Open circuit – The output port is in a non-conductive state when its current status is open circuit. The current
status of an output port can be changed by, for example, an action rule.
Output as Grounded circuit – The output port is in a conductive state when its current status is grounded circuit.
Port Status
The list on the System Options > Ports & Devices > Port Status page shows the status of the product's input and output ports.

Maintenance

The Axis product provides several maintenance functions. These are available under System Options > Maintenance.
Click Restart to perform a correct restart if the Axis product is not behaving as expected. This will not affect any of the current
settings.
58

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q6055-c

Table of Contents